Technical Features; Internal Connections; 4: S81-Pu002 Power Supply Set - Honeywell H-S81-HS Operation Manual

Industrial fire panel
Hide thumbs Also See for H-S81-HS:
Table of Contents

Advertisement

Parts of the H-S81-HS System

Technical Features

• Input voltage
• Free-air operating temperature
• Relative humidity
• Efficiency
• Protection class
• Dimensions
• Flammability
• Battery voltage
• Battery current
• VBAT Ripple
• Resistance to main voltage dips
• Maximum battery circuit resistance
• Maximum battery capacity
• Maximum current to batteries
• Current to the load

Internal Connections

Terminal block
Terminal
M1
TB1
M2
M3
Terminal block
Terminal
M1
TB2
M2
M3
Terminal block
Terminal
M1
M2
TB3
M3
M4
2.1.4 S81-PU002 Power Supply Set
This power supply set is able to supply a maximum current of 32 amperes, duplicated to the load,
and to control and charge two 12 Volt batteries with maximum capacity of 120Ah. Battery maxi-
mum charge current is 6 amperes. Under normal operating conditions, a simplified test is carried
out every 30 seconds in order to check the proper presence of the batteries. A full test, instead, is
carried out every hour in order to check electrical connections and battery efficiency. During bat-
tery trickle charge, battery voltage is compensated automatically according to the temperature. In
case of mains voltage failure, batteries are automatically switched to the load without any interrup-
tions. Should the full charge stage exceed 24 hours, the power supply unit will signal a battery fault.
In case of primary power supply failure, the system will shut batteries down when the on-load volt-
age is lower than 18VDC in order to avoid damaging the batteries. The set features seven open col-
lector outputs for replicating the various types of faults to the alarm control panel, along with a
RS232 port for the connection to the configuration program Test-PUA009. Ho-swapping is possi-
ble for both the 4 AC/DC converters and the battery charger (Hot Plug).
30
22-28 VDC
-5 °C - 50 °C
93% non-condensing
> 83%
IP20
200mm x 110mm x 60mm
UL94V2
26.2 to 28.7 VDC, compensated automatically
(1/2/4A) Adjustable through dip switch
< 100mV pK-pK at maximum current
>=20mS at maximum current (with PU-A0005)
1.5 ohm
65 Ah
Limited automatically
protected by 20A internal fuse
CONNECTION OF STATUS OPEN COLLECTOR OUTPUTS
Name
Function
PSU1 Fault
Open collector output - power supply unit section fault
PSU2 Fault
Open collector output - battery charger section fault
Charge Status
Battery charge status output (energized during the full charge stage).
CONNECTION OF POWER SUPPLY UNIT STATUS INDICATION
Name
Function
AND-Failure
Input of voltage failure to all power supply sets
OR-Failure
Input of voltage failure to one power supply set
-V Out
M1 and M2 input common
CONNECTIONS TO THE BATTERIES AND TO THE LOAD
Name
Function
- V. Bat
Battery negative
+V. Bat
Battery positive
- V. Load
Negative of power supply to the Load
+V. Load
Positive of power supply to the Load
H-S81-HS Installation & Operation Manual — P/N LS10114-000HI-E:A 2/24/2015