21. After aligning the Bridge Unit with the printer, check the following:
0.12 in (3 mm)
The gap between the bottom of the EJ Unit
or less
cutout and the bottom of the Bridge Unit paper
insertion portion must be 0.12 in (3 mm) or less.
(Depending on the flooring of the installation site,
the printer may sink and cause a gap larger than
0.12 in [3 mm]. In this case, adjust the height by
adjusting the casters [see
Joint Hook Guide Pin
The tip of the Joint Hook Guide Pin must touch the upper
edge of the Cutout of the Bridge Unit.
Step
27].)
NG
OK
NG
22. Push the Bridge Unit into the printer to connect them.
When performing this step, you should feel slight resistance
C H E C K
because the Bridge Unit plate makes contact with the tip of
P O I N T
the Joint Hook Guide Pin. If you do not feel resistance, the
Bridge Unit height may be too high. Check the points in