Errors In The Ethercat Master Function Module - Omron NJ Series Troubleshooting Manual

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Event code
Event name
94040000 hex
Tag Data Link
Started
94050000 hex
Link
Detected
94060000 hex
Restarting
Ethernet Port
94070000 hex
Tag Data Link
All Run
94080000 hex
IP Address
Fixed
94090000 hex
BOOTP Cli-
ent Started
940A0000 hex
FTP Server
Started
940B0000 hex
NTP Client
Started
940C0000 hex
SNMP
Started
3-1-5

Errors in the EtherCAT Master Function Module

Built-in EtherCAT Master in CPU Unit
Event code
Event name
04400000 hex
Communica-
tions Control-
ler Failure
14400000 hex
MAC
Address
Error
44010000 hex
EtherCAT
Fault
NJ-series Troubleshooting Manual (W503)
Meaning
Assumed cause
Tag data links were
• Tag data links were started by
started by Network
Network Configurator or manip-
Configurator or
ulation of a system-defined
manipulation of a
variable.
system-defined
variable. Or, the
data link table was
downloaded from
the Network Config-
urator again.
Establishment of an
• Establishment of an Ethernet
Ethernet link was
link was detected.
detected.
The built-in Ether-
• The built-in EtherNet/IP port
Net/IP port was
was restarted.
restarted.
Tag data link con-
• Tag data link connections to all
nections to all
target nodes have been estab-
nodes have been
lished.
established.
The correct IP
• The correct IP address has
address has been
been determined and Ethernet
determined and
communications can start.
Ethernet communi-
cations can start.
The BOOTP client
• The BOOTP client started
started requesting
requesting an IP address.
an IP address.
The FTP agent
• The FTP agent started nor-
started normally.
mally.
The NTP client
• The NTP client started normally
started normally
and a request for the NTP
and a request for
server to obtain the time
the NTP server to
started.
obtain the time
started.
The SNMP agent
• The SNMP agent started nor-
started normally.
mally.
Meaning
Assumed cause
An error was
• The CPU Unit has failed.
detected in the
hardware test at
startup.
The MAC address
• The CPU Unit has failed.
is incorrect.
A fatal error was
• Software is corrupted.
detected in the
EtherCAT Master
Function Module.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
NJ-series
CPU Unit
Built-in Ether-
Net/IP Port
User's Manual
(Cat. No.
W506)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
Level
Maj
Prt
Min
Obs
Info
S
NJ-series
CPU Unit
Built-in Ether-
CAT Port
User's Manual
(Cat. No.
W505)
S
Same as
above.
S
Same as
above.
Reference
3
Reference
3-71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj501-1500Nj501-1400Nj501-1300Nj301-1200Nj301-1100

Table of Contents