Omron NJ Series Troubleshooting Manual page 136

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
10300000 hex
EtherCAT
(Ver. 1.03)
Slave
Restore
Operation
Failed
64200000 hex
Emergency
Message
Detected
842D 0000 hex
EtherCAT
Message
Error
94400000 hex
Slave Dis-
connected
94410000 hex
Slave Con-
nected
94430000 hex
Errors Reset
94440000 hex
Slave Dis-
(Ver. 1.04)
abled
94450000 hex
Slave
(Ver. 1.04)
Enabled
3-74
Meaning
Assumed cause
The restore opera-
• There is no connection
tion for an Ether-
between the EtherCAT master
CAT slave ended in
and the slave (Link OFF).
an error.
• An error caused an incorrect
EtherCAT master status.
• The EtherCAT network configu-
ration information does not
agree with the physical net-
work configuration.
• The request to the EtherCAT
slave failed.
• The EtherCAT master was tem-
porarily unable to perform the
processing because it was exe-
cuting other processing.
• Initialization of the EtherCAT
slave failed.
• It was not possible to write the
backup parameters to the
MX2/RX Series Inverter.
• It was not possible to write the
backup parameters to the
EtherCAT slave.
• Incorrect backup data was
detected.
• The EtherCAT network configu-
ration in the backup data does
not agree with the physical net-
work configuration.
An emergency
• An emergency message was
message was
received from a slave.
detected.
An error occurred in
• Refer to the attached informa-
a message commu-
tion to check the error.
nications with the
slave.
A slave was discon-
• An operation to disconnect the
nected for a discon-
slave was executed from the
nection command.
Sysmac Studio.
• The EC_DisconnectSlave
instruction was executed.
A slave was recon-
• An operation to reconnect the
nected for a recon-
slave was executed from the
nection command.
Sysmac Studio.
• The EC_ConnectSlave instruc-
tion was executed.
A command was
• An error reset operation was
received to reset
performed from the Sysmac
errors.
Studio.
• The ResetECError instruction
was executed.
The EtherCAT
• The EC_ChangeEnableSetting
Slave was disabled.
instruction was executed.
The EtherCAT
• The EC_ChangeEnableSetting
Slave was enabled.
instruction was executed.
Level
Maj
Prt
Min
Obs Info
S
NJ-series
CPU Unit
Built-in Ether-
CAT Port
User's Manual
(Cat. No.
W505)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
NJ-series Troubleshooting Manual (W503)