Omron NJ Series Troubleshooting Manual page 100

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
54015493 hex
Master Axis Offset
Out of Range
54015494 hex
Slave Axis Offset
Out of Range
54015495 hex
Command Current
Position Count
Selection Out of
Range
54015496 hex
Master Axis Gear
Ratio Numerator
Out of Range
54015497 hex
Master Axis Gear
Ratio Denomina-
tor Out of Range
54015498 hex
Auxiliary Axis Gear
Ratio Numerator
Out of Range
54015499 hex
Auxiliary Axis Gear
Ratio Denomina-
tor Out of Range
5401549A hex
Master Axis Posi-
tion Type Selec-
tion Out of Range
5401549B hex
Auxiliary Axis Posi-
tion Type Selec-
tion Out of Range
5401549C hex
Target Position
Ring Counter Out
of Range
5401549D hex
Axes Group Com-
(Ver. 1.01)
position Axis Set-
ting Out of Range
5401549E hex
Axis Use Setting
(Ver. 1.04)
Out of Range
54015700 hex
Homing Parame-
(Ver. 1.03)
ter Setting Out of
Range
3-38
Meaning
The parameter specified for
• The instruction input
the MasterOffset input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• The instruction input
the SlaveOffset input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the CmdPosMode input
variable to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the RatioNumeratorMaster
input variable to a motion
control instruction is out of
range.
The parameter specified for
• Instruction input
the RatioDenominatorMas-
ter input variable to a
motion control instruction is
out of range.
The parameter specified for
• Instruction input
the RatioNumeratorAuxil-
iary input variable to a
motion control instruction is
out of range.
The parameter specified for
• Instruction input
the RatioDenominatorAuxil-
iary input variable to a
motion control instruction is
out of range.
The parameter specified for
• Instruction input
the ReferenceTypeMaster
input variable to a motion
control instruction is out of
range.
The parameter specified for
• Instruction input
the ReferenceTypeAuxil-
iary input variable to a
motion control instruction is
out of range.
Operation is not possible
• High-speed homing
because the target position
is out of range for the ring
counter of the executed
instruction.
The parameter specified for
• Instruction input
the Axes input variable to a
motion control instruction is
out of range.
The parameter specified for
• Instruction input
the AxisUse input variable
to a motion control instruc-
tion is out of range.
The parameter specified for
• Instruction input
the HomingParameter input
variable to a motion control
instruction is out of range.
Assumed cause
Maj
Prt
parameter exceeded
the range of signed
40-bit data when it is
converted to pulses.
parameter exceeded
the range of signed
40-bit data when it is
converted to pulses.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
was executed when 0
was not included in
the ring counter.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
NJ-series Troubleshooting Manual (W503)
Level
Refer-
ence
Min
Obs
Info
S
NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj501-1500Nj501-1400Nj501-1300Nj301-1200Nj301-1100

Table of Contents