Omron NJ Series Troubleshooting Manual page 95

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Event code
Event name
54015463 hex
Motion Control
Instruction Re-exe-
cution Disabled
(SlaveOffset)
54015464 hex
Motion Control
Instruction Re-exe-
cution Disabled
(SlaveScaling)
54015465 hex
Motion Control
Instruction Re-exe-
cution Disabled
(StartPosition)
54015466 hex
Instruction Execu-
tion Error with
Undefined Home
54015467 hex
Motion Control
Instruction Re-exe-
cution Disabled
(Position Type)
54015468 hex
Unused Axis Spec-
ification for Master
Axis
54015469 hex
First Position Set-
ting Out of Range
5401546A hex
Last Position Set-
ting Out of Range
5401546B hex
Illegal First/Last
Position Size Rela-
tionship (Linear
Mode)
NJ-series Troubleshooting Manual (W503)
Meaning
An attempt was made to
• A parameter for an
change the SlaveOffset
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
An attempt was made to
• A parameter for an
change the SlaveScaling
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
An attempt was made to
• A parameter for an
change the StartPosition
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
High-speed homing or an
• High-speed homing
interpolation instruction
was executed when home
was undefined.
• An interpolation
An attempt was made to
• A parameter for an
change the ReferenceType
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
The master axis specified
• The master axis speci-
for a motion control instruc-
tion is an unused axis.
The parameter specified for
• Instruction input
the FirstPosition input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the LastPosition input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• The value of the Last-
the LastPosition input vari-
able to a motion control
instruction is smaller than
the parameter specified for
the FirstPosition input vari-
able.
Assumed cause
Maj
Prt
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
was executed when
home was undefined.
instruction was exe-
cuted for an axes
group that includes an
axis with no defined
home.
input variable that can-
not be changed for re-
execution was
changed.
fied for a motion con-
trol instruction is an
unused axis.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
Position input parame-
ter is less than the
value of the FirstPosi-
tion input variable for
the instruction when
the Count Mode is set
to Linear Mode.
3 Error Tables
Level
Refer-
ence
Min
Obs
Info
S
NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
3-33