Cleaning and caring for the unit

6.9.1 Cleaning the yellow filter mat

NOTICE
Requirements Disconnect the recirculation and associated unit from power
86
Image: Recirculation hood filter
a Condensation baffle
b Filter drawer
c Air outlet
d Recirculation hood
Risk of property damage from improper cleaning
Do not use a fabric softener when cleaning the yellow filter mat.
Always wash the yellow filter mate separately.
Reinstall only a fully dried filter mat.
Unit has cooled down
Step ladder set up securely
1. Remove yellow filter mat, incl. holder.
2. Remove yellow filter mate from holder.
Manual washing
1. Allow the yellow filter pad to soak for 5 minutes in a basin of warm
water and commercially available cleaning agent.
2. Knead it thoroughly several times, but do not wring it.
3. Wash it out under clear, warm water and press out the water.
4. Repeat both procedures, until the water does not show any more
discolouration.
5. After washing the filter pad, dry it on a smooth, horizontal
substrate at ground level.
Machine washing
1. Before washing the yellow filter mat, spray it thoroughly with a
grease remover and allow it to act.
Operating instructions
d
c
b
a
h
g
e Vapor inlet
f Filter mat (yellow)
g Air filter
h Activated charcoal filter
f
e