SERVICE PROGRAM MODE
Mode No.
2
(Class 1, 2, and 3)
400*
7
Jam Recovery
8
Toner Revital
401*
Cleaning Bias LL2
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
8
Toner Revital
402*
Cleaning Bias NN1
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
8
Toner Revital
403*
Cleaning Bias NN2
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
8
Toner Revital
404*
Cleaning Bias HH
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
Function / [ Setting ]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
3.5 < AH ≤ 8.0 (this is the 'LL2' humidity range) DFU
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
8.0 < AH ≤ 14 (this is the 'NN1' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
14 < AH ≤ 19 (this is the 'NN2' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
19 < AH (this is the 'HH' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
5-10
10 February, 2005