10 February, 2005
Mode No.
2
(Class 1, 2, and 3)
981
Toner Revitalization
1
Job_Interruption
2
Job_ End
982
Dev. Motor Control
1
Speed Shift Time
2
Dev.CL_Off Time
983
Development Fan Continued Time
1
Function / [ Setting ]
Specifies the number of prints for executing toner
revitalization in the middle of a job.
[0 ~ 200 / 100 / 10 /step]
0: Disables job interruption.
For A4 SEF, the counter counts twice.
Specifies the number of prints for executing toner
revitalization at the end of a job.
[0 ~ 100 / 20 / 1 /step]
0: Disables toner refresh at end of a job.
For A4 SEF, the counter counts twice.
Specifies the interval for changing the development
motor speed from half speed to normal speed.
[0 ~ 500 / 100 / 10 ms/step] DFU
Specifies the interval until turning off the development
clutch after turning off the development motor.
[−150 ~ 0 / −60 / 10 ms/step] DFU
Sets more time for development fan operation.
[0 ~ 900 / 0 / 10 sec /step]
When the machine operates with high CV in a high-
temperature and high-humidity environment, dirty
background can occur. Because of this, the fan operates
for a longer interval to decrease the development unit
temperature and to prevent dirty background.