Table of Contents

Advertisement

OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
4
On the LinkWare menu select Utilities > OptiFiber
Utilities > Create Software Update MMC.
5
Locate and select the .ofu file you downloaded; then
click Open.
6
Locate and select the memory card drive; then click OK.
LinkWare unzips the update file and copies the files to
the memory card.
W
If you remove the memory card from the MMC
reader before the files are completely copied the
Windows operating system may report an error
and OptiFiber shows the message "Bad update
file". If this happens, repeat steps 4 through 6;
then leave the card in the reader for a minute or
so to ensure the files are completely copied.
7
Put the memory card into the OptiFiber tester.
8
Install a module in the OptiFiber mainframe, then turn
on the tester.
12-4
Caution
Press F on OptiFiber; then select Install Software
9
Update. The tester makes initial choices on which
software to install based on the versions currently
installed in the mainframe and the module. Generally,
you should not change these choices except to select
languages to install or remove.
10 Press E Start to start the update process.
11 The OptiFiber tester reboots after the update is
complete. To verify the update, press A Version Info
from the HOME screen.
12 If you have additional modules to update, insert each
module and repeat steps 9, 10, and 11.