Sign In
Upload
Manuals
Brands
Fluke Manuals
Measuring Instruments
OC3port Plus
Fluke OC3port Plus Manuals
Manuals and User Guides for Fluke OC3port Plus. We have
1
Fluke OC3port Plus manual available for free PDF download: User Manual
Fluke
OC3port Plus
User Manual
Fluke OC3port Plus User Manual (248 pages)
Handheld OC3 / ATM Network Analyzer
Brand:
Fluke
| Category:
Measuring Instruments
| Size: 0.94 MB
Table of Contents
Table of Contents
4
Chapter 1
16
How to Use this Manual
16
Introduction
16
About this Manual
16
What You Should Know
16
Who this Manual Is for
16
Notations and Typographical Conventions
17
Oc3Port Plus Features and Capabilities
17
The Oc3Port Plus Handheld Tester: at a Glance
19
Specifications
20
Notices, Warnings, Operating Restrictions
23
Checking Your Package
24
Laser Operation
24
Technical Support
24
Service Center Repair
25
Chapter 2
28
The Connector Panel
28
The Front Panel
29
The LCD
29
Direct Access Keys
30
Status Section
32
System Control Keys
35
Getting Acquainted with the Oc3Port Plus Menus
37
Accessing a Menu
38
Using the Directional Arrow Keys
39
Scrolling through Menu Options
39
Changing the Setting for an Option
40
Editing the Setting for an Option
41
Accessing Oc3Port Plus Submenus
42
Exiting Oc3Port Plus Submenus
43
Getting Started
28
Introduction
28
Oc3Port Plus Controls and Connections
28
Connecting the Oc3Port Plus
43
Connecting the Oc3Port Plus to Network Devices
44
Connecting to Remote Devices
44
Connecting the Oc3Port Plus to a PC or Laptop
44
Connecting the Oc3Port Plus to a Modem
45
Connecting to a Printer
45
Connecting to an External Power Supply
46
Introduction
50
Programming the Overall Operation of the Oc3Port Plus
50
Setting up and Operating the Oc3Port Plus
50
Chapter 3
51
Changing the Default Scrolling Method
51
Turning on the Warning Buzzer
52
Setting the System Date and Time
52
Setting the Communications Speed
53
Turning off the Automatic Diagnostic Tests
54
Parameter Sets
55
Creating a Parameter Set
55
Naming a Parameter Set
57
Switching to a Different Parameter Set
58
Editing a Parameter Set
58
Performing Basic Operations
59
Turning on the Oc3Port Plus
59
Turning on the Laser Transmitter
61
Returning to the Introductory Display
62
Resetting the Oc3Port Plus
62
Restoring Factory Default Settings
62
Clearing the Error Counters
63
Responding to Low Battery Warnings
63
Obtaining Information about Your Oc3Port Plus
64
Storing and Retrieving Test Results
64
Manually Storing Test Results
65
Automatically Storing Test Results in Memory
66
Displaying Stored Test Results
69
Deleting Stored Test Results
71
Deleting a Single Record
72
Deleting All Stored Records in a Test Group
72
Printing, Downloading, and Remote Control
73
Connecting to the Serial Port
73
Printing Reports and Configuration Information
76
Controlling the Oc3Port Plus Remotely
77
Pausing a Print Job
77
Preventing a Report from Being Printed
77
Running the Automatic Diagnostic Tests
78
Chapter 4
82
Differences between SONET OC3 STS-3C and SDH STM-1
82
Changing the Framing Format
83
Changing the S-Bit Values (Optional)
84
Setting up for Testing STS-3C and STM-1 Signals
86
Generating Automatic Alarms
86
Setting the Transmit Clock Source
88
Scrambling Payloads
89
Changing the Threshold Setting for Counters
90
Enabling/Disabling PATH FERF Support
91
Monitoring Incoming STS-3C or STM-1 Signals
92
Inserting Errors
94
Modifying the Value of the Payload Pointer
96
Generating Alarms
97
Transmitting an Alarm
98
Turning off an Alarm
99
Viewing Alarms Stored in the Alarm Log
99
Removing All Alarms from the Alarm Log
101
Responding to an LOS Condition
102
In-Service Signal Monitoring
102
SONET/SDH Configuration and Testing
82
Introduction
82
Configuring the Framing Format
82
Chapter 5
108
Introduction
108
Configuring a Receive Filter
108
Configuring an ATM Cell Transmission Stream
112
Some Suggestions for Configuring Multiple Cell Streams
122
Configuring a VBR / Poisson Transmission Source
123
Other ATM Configuration Options
123
Payload Scrambling Option
124
Coset Polynomial Option
125
Correction Algorithm Option
126
Background Traffic Option
127
Header Type Option
127
Changing the Form for Expressing the PCR and SCR
129
Large Transmit Queue
130
Configuring for ATM Network Testing
108
Testing ATM Networks
132
Introduction
132
Starting Stream Transmission
135
Chapter 6
136
Transmitting OAM Cells on a Single Circuit
136
Transmitting OAM Cells on Multiple Circuits
138
Monitoring an ATM Network
140
Monitoring ATM Traffic with a Receive Filter
140
Capturing ATM Cells
145
Configuring the Oc3Port Plus for Capturing ATM Cells
146
Starting a Cell Capture
150
Looking at the Captured Cells
151
Displaying the Results of the Previous Cell Capture
153
Capturing ILMI Cells
153
Configuring the Oc3Port Plus for Capturing ILMI Cells
154
Looking at Captured ILMI Cells
158
Starting an ILMI Cell Capture
158
Capturing OAM Cells
159
Configuring the Oc3Port Plus for Capturing OAM Cells
159
Starting an OAM Cell Capture
160
Looking at Captured OAM Cells
161
Searching for AAL Traffic on an ATM Network
162
Scanning Circuits for ATM Activity
165
Setting up an ATM Activity Scan
165
Scanning an ATM Circuit
169
Printing the Results of an Activity Scan
171
Displaying the Results of the Previous Activity Scan
173
Using the ATM Traffic Templates
173
ATM Traffic Templates: a Description
173
20% Spread
173
BER Test
173
Police 10Mbs
173
Rampdown
173
20% Spread
174
BER Test
174
Police 10Mbs
174
Rampdown
174
Selecting and Loading an ATM Traffic Template
174
Starting Transmission with a Loaded Template
176
Editing a Template
177
Quality of Service Tests
177
Cell Loss Test
178
Setting up a Cell Loss Test
178
Running a Cell Loss Test
181
Re-Running a Cell Loss Test
182
Remote Cell Loss Test
182
Setting up a Remote Cell Loss Test
183
Setting up the Master Unit
184
Setting up the Slave Unit
190
Running a Remote Cell Loss Test
195
Exiting and Returning to a Test in Progress
196
Understanding Cell Loss Test Results
196
1-Point CDV Test
197
Cell Delay Variation Tests
197
Setting up a 1-Point CDV Test
197
Running a 1-Point CDV Test
199
2-Point CDV Test
201
Setting up a 2-Point CDV Test
201
Running a 2-Point CDV Test
202
Cell Transfer Delay Test
203
Setting up a Cell Transfer Delay Test
204
Running a Cell Transfer Delay Test
205
Exiting a Cell Transfer Delay in Progress Test
206
Understanding Cell Transfer Delay Test Results
206
Bit Error Rate Test (BERT)
207
Setting up a BERT Test
207
Creating Your Own BERT Test Pattern
209
Running an ATM BERT Test
210
Injecting Individual BERT Errors
211
IP Ping Test
212
Setting up the Oc3Port Plus to Send an IP Message
212
Sending an IP Message
216
Receiving an IP Message
218
Appendices
220
A Applications
220
Boc3Port Plus ATM Transmission
220
C Glossary
220
Index
240
Advertisement
Advertisement
Related Products
Fluke OptiFiber PRO OTDR
Fluke OF-500-03 OptiFiber
Fluke OptiView II Series
Fluke OptiFiber Pro
Fluke OFP2-100-S
Fluke OFP2-100-Q
Fluke OFP2-100-M
Fluke OptiView III Series
Fluke OptiView Series
Fluke OptiView
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL