Fluke OF-500-01 OptiFiber Technical Reference Handbook page 137

Of-500 series optifiber
Hide thumbs Also See for OF-500-01 OptiFiber:
Table of Contents

Advertisement

A
The length of the channel, including the launch fiber.
The FIBER LENGTH shown is the actual length of the
channel rounded to the nearest meter or foot (not
the sum of the displayed segment lengths).
B
The far end of the channel. The name is set by the END 1
or END 2 setting on the Job tab in Setup.
Note
Using the ChannelMap Function
ChannelMap Diagram Features
C
The length of a segment or patch cord rounded to the
nearest meter or foot.
D
D
Press
to add a comment to the ChannelMap results.
E
A reflective event, usually a connector. Could also be a
mechanical splice or a reflective fault such as a sharp
bend or a crack in the fiber.
F
The near end of the channel. The name is set by the END
1 or END 2 setting on the Job tab in Setup.
4
4-5