2.
Crimp the blade terminal.
Insert wires to a blade terminal, and check that the wires come out for about 0 to 0.5 mm from a sleeve.
Check the condition of the blade terminal after crimping. Do not use a blade terminal of which the crimping is
inappropriate, or the face is damaged.
Blade terminals commercially available (as of January 2017)
• Phoenix Contact Co., Ltd.
Cable gauge
2
(mm
)
With insulation sleeve
0.3
AI 0,34-10TQ
0.5
AI 0,5-10WH
0.75
AI 0,75-10GY
1
AI 1-10RD
1.25, 1.5
AI 1, 5-10BK
0.75 (two-wire
AI-TWIN 2×0,75-10GY
product)
*1
A ferrule terminal with an insulation sleeve compatible with the MTW wire which has a thick wire insulation.
*2
Applicable for terminals A1, B1, C1, A2, B2, C2.
• NICHIFU Co., Ltd.
2
Cable gauge (mm
)
0.3 to 0.75
3.
Insert the wires into a socket.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
64
2. INSTALLATION AND WIRING
2.6 Control circuit
Ferrule terminal model
Without insulation
sleeve
A 0,75-10
A 1-10
A 1, 5-10
Blade terminal
Insulation cap product
product number
BT 0.75-11
VC 0.75
Damaged
Crumpled tip
*1
For UL wire
AI 0,5-10WH-GB
AI 0,75-10GY-GB
AI 1-10RD/1000GB
AI 1,5-10BK/1000GB
Crimping tool product
number
number
NH 69
When using a single wire or stranded wires without a blade
terminal, push the open/close button all the way down with a
flathead screwdriver, and insert the wire.
Unstranded
wires
Wires are not inserted
into the sleeve
Crimping tool
name
CRIMPFOX 6
*2
Open/close button
Flathead screwdriver