Mitsubishi Electric FR-F820-00046 Instruction Manual page 204

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

 GOT initial setting (RS-485 terminals) (Pr.999 = "11, 13")
Pr.
79
Operation mode selection
332
RS-485 communication speed
RS-485 communication stop bit length / data
333
length
334
RS-485 communication parity check selection
335
RS-485 communication retry count
336
RS-485 communication check time interval
337
RS-485 communication waiting time setting
340
Communication startup mode selection
341
RS-485 communication CR/LF selection
414
PLC function operation selection
549
Protocol selection
*1
When Pr.414 = "1", the setting value is not changed.
 Initial setting with the GOT2000 series
• When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set Pr.999
= "11" to configure the GOT initial setting.
• When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT
setting and the GOT automatic connection is not used, set Pr.999 = "13" to configure the GOT initial setting. (Refer to
523.)
 Initial setting with the GOT1000 series
• Set Pr.999 = "11" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For the details of connection with GOT, refer to the Instruction Manual of GOT.
 Rated frequency (Pr.999 = "20" (50 Hz) or "21" (60 Hz))
Pr.
3
Base frequency
4
Multi-speed setting (high speed)
20
Acceleration/deceleration reference frequency 60 Hz
37
Speed display
55
Frequency monitoring reference
Stall prevention operation reduction starting
66
frequency
125 (903)
Terminal 2 frequency setting gain frequency
126 (905)
Terminal 4 frequency setting gain frequency
263
Subtraction starting frequency
Power failure deceleration time switchover
266
frequency
386
Frequency for maximum input pulse
390
% setting reference frequency
505
Speed setting reference
584
Auxiliary motor 1 starting frequency
585
Auxiliary motor 2 starting frequency
586
Auxiliary motor 3 starting frequency
C14 (918)
Terminal 1 gain frequency (speed)
Emergency drive running speed after retry
1013
reset
Name
Initial value
0
96
1
2
1
0 s
9999
0
1
0
0
Initial value
Name
FM type CA type
60 Hz
60 Hz
0
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Pr.999 = "11"
Pr.999 = "13"
0
0
192
1152
10
0
1
1
9999
9999
9999
9999
0 ms
0 ms
1
1
1
1
*1
2
0
0
Pr.999 = "21"
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
0
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
5.4 (E) Environment setting parameters
Refer to page
228
482
237
482
462
498
page
Pr.999 = "20"
Refer to page
528
249
216
286
297
273
339
458
245
511
286
430
339
263
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
203

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents