Mitsubishi Electric FR-F820-00046 Instruction Manual page 160

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

 D: Parameters for the setting of
operation command and
frequency command
Parameters for setting the command source to the inverter,
and the motor driving frequency and torque.
Pr.
Pr.
group
D000
79
Operation mode selection
Communication startup mode
D001
340
selection
Communication operation
D010
338
command source
Communication speed command
D011
339
source
NET mode operation command
D012
550
source selection
PU mode operation command
D013
551
source selection
Reverse rotation prevention
D020
78
selection
D100
291
Pulse train I/O selection
D101
384
Input pulse division scaling factor
D110
385
Frequency for zero input pulse
Frequency for maximum input
D111
386
pulse
D200
15
Jog frequency
Multi-speed input compensation
D300
28
selection
Multi-speed setting (high
D301
4
Simple
Simple
Simple
speed)
Multi-speed setting (middle
D302
5
Simple
Simple
Simple
speed)
Multi-speed setting (low
D303
6
Simple
Simple
Simple
speed)
D304 to
24 to
Multi-speed setting (4 speed to 7
D307
27
speed)
D308 to
232 to
Multi-speed setting (8 speed to 15
D315
239
speed)
 H: Protective function parameter
Parameters to protect the motor and the inverter.
Pr.
Pr.
group
Electronic thermal O/L
H000
9
Simple
Simple
Simple
relay
First free thermal reduction
H001
600
frequency 1
H002
601
First free thermal reduction ratio 1
First free thermal reduction
H003
602
frequency 2
H004
603
First free thermal reduction ratio 2
First free thermal reduction
H005
604
frequency 3
H006
607
Motor permissible load level
Second electronic thermal O/L
H010
51
relay
Refer
Name
to page
228,
Simple
Simple
Simple
237
237
239
239
239
239
245
245,
297
245
245
245
248
249
249
249
249
249
249
Refer
Name
to page
252,
366,
375
252
252
252
252
252
252
252,
366,
375
Pr.
Pr.
group
Second free thermal reduction
H011
692
frequency 1
Second free thermal reduction
H012
693
ratio 1
Second free thermal reduction
H013
694
frequency 2
Second free thermal reduction
H014
695
ratio 2
Second free thermal reduction
H015
696
frequency 3
Second motor permissible load
H016
608
level
H020
561
PTC thermistor protection level
PTC thermistor protection
H021
1016
detection time
H100
244
Cooling fan operation selection
Earth (ground) fault detection at
H101
249
start
H102
598
Undervoltage level
H103
997
Fault initiation
Output phase loss protection
H200
251
selection
Input phase loss protection
*3
H201
872
selection
H300
65
Retry selection
Number of retries at fault
H301
67
occurrence
H302
68
Retry waiting time
H303
69
Retry count display erase
*3
H320
Emergency drive mode selection
523
*3
H321
Emergency drive running speed
524
Emergency drive dedicated retry
*3
H322
515
count
Emergency drive running speed
*3
H323
1013
after retry reset
Emergency drive dedicated
*3
H324
514
waiting time
H400
1
Maximum frequency
H401
2
Minimum frequency
H402
18
High speed maximum frequency
H420
31
Frequency jump 1A
H421
32
Frequency jump 1B
H422
33
Frequency jump 2A
H423
34
Frequency jump 2B
H424
35
Frequency jump 3A
H425
36
Frequency jump 3B
H429
552
Frequency jump range
H500
22
Stall prevention operation level
Stall prevention operation
H501
156
selection
Load characteristics measurement
H520
1480
mode
Load characteristics load
H521
1481
reference 1
Load characteristics load
H522
1482
reference 2
Load characteristics load
H523
1483
reference 3
Load characteristics load
H524
1484
reference 4
Refer
Name
to page
252
252
252
252
252
252
252
252
258
259
260
260
260
260
261
261
261
261
263
263
263
263
263
271
Simple
Simple
Simple
Simple
Simple
Simple
271
271
272
272
272
272
272
272
272
273
273
281
281
281
281
281
5. PARAMETERS
5.1 Parameter list
1
2
3
4
5
6
7
8
9
10
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents