Mitsubishi Electric FR-F820-00046 Instruction Manual page 291

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Monitor item
PLC function user
monitor 1
PLC function user
monitor 2
PLC function user
monitor 3
Station number (RS-
485 terminals)
Station number (PU)
Station number (CC-
Link)
Power saving effect
Cumulative energy
saving
PID set point
PID measured value
PID deviation
Input terminal status
Output terminal
status
Option input terminal
*9
status
Option output
*9
terminal status
Option input terminal
status 1 (for
*9
communication)
Option input terminal
status 2 (for
*9
communication)
Option output
terminal status (for
*9
communication)
Motor thermal load
factor
Inverter thermal load
factor
PTC thermistor
resistance
PID measured value
2
Emergency drive
*7
status
290
5. PARAMETERS
5.8 (M) Item and output signal for monitoring
Increment
Pr.
RS-485
and unit
setting
40
H28
Increment set
41
H29
in the register
SD1215
42
H2A
1
43
H2B
1
44
H2C
1
45
H2D
Increment
50
H32
and unit vary
depending on
51
H33
the parameter
settings.
0.1%
52
H34
0.1%
53
H35
0.1%
54
H36
*10
H0F
*17
55
*11
H10
56
57
*12
H3A
*13
H3B
*14
H3C
0.1%
61
H3D
0.1%
62
H3E
0.01 kΩ
64
H40
0.1%
67
H43
1
68
H44
Negative
MODBUS
indication
RTU
(-)
The user-designated monitor item is displayed using the
40240
PLC function.
Each value of the following special registers is displayed.
40241
SD1216: displayed with the setting value "40"
SD1217: displayed with the setting value "41"
SD1218: displayed with the setting value "42"
40242
(Refer to the PLC Function Programming Manual.)
The station number (0 to 31) of the inverter enabling
40243
communication via the RS-485 terminals is displayed.
The station number (0 to 31) of the inverter enabling
40244
communication via the PU connector is displayed.
The station number of the inverter enabling CC-Link
40245
communication is displayed. ("0" is displayed when the
FR-A8NS is not installed.)
40250
The energy saving effect monitoring is enabled. The item
to monitor is selectable from among the saved power, the
average energy saving, and the energy cost savings.
40251
Some of them can be displayed as a percentage
according to the parameter settings. (Refer to
40252
The set point, measured value, and deviation during PID
40253
control operation is displayed. (Refer to
40254
The ON/OFF state of the input terminals on the inverter
*10
is displayed. (Refer to
40215
on the DU.)
The ON/OFF state of the output terminals on the inverter
*11
is displayed. (Refer to
40216
on the DU.)
The ON/OFF state of the input terminals on the digital
input option (FR-A8AX) is displayed on the DU. (Refer to
page 293
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
A8AR) is displayed on the DU. (Refer to
details.)
The ON/OFF state of the input terminals X0 to X15 on the
digital input option (FR-A8AX) is monitored via RS-485
*12
40258
communication or other communication when the
communication option is installed.
The ON/OFF state of the input terminal DY on the digital
input option (FR-A8AX) is monitored via RS-485
*13
40259
communication or other communication when the
communication option is installed.
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
*14
A8AR) is monitored via RS-485 communication or other
40260
communication when the communication option is
installed.
The accumulated heat value of the motor thermal O/L
relay is displayed.
40261
The motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
40262
The inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PTC thermistor resistance is displayed when Pr.561
40264
PTC thermistor protection level ≠ 9999. (The output
voltage is displayed when Pr.561 = 9999.)
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
40267
operating conditions are not satisfied. (Refer to
412.)
Displays the emergency drive status. (Refer to
40268
263.)
Description
page
page 293
for details of indication
page 293
for details of indication
for details.)
page 293
page
306.)
412.)
for
page
page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents