 List of the target parameters for the motor parameter initialization
• The setting of the parameters in the following table is changed to the setting for PM motor control by performing the motor
parameter initialization using IPM initialization or Pr.998 PM parameter initialization. The changed settings differ
according to the specification (capacity) of the PM motor used.
• Performing Parameter clear or All parameter clear resets these parameter settings to the settings required to drive an
induction motor.
Pr.
Name
1
Maximum frequency
Multi-speed setting (high
4
speed)
9
Electronic thermal O/L relay
13
Starting frequency
15
Jog frequency
High speed maximum
18
frequency
Acceleration/deceleration
20
reference frequency
Stall prevention operation
22
level
37
Speed display
Frequency monitoring
55
reference
56
Current monitoring reference
71
Applied motor
80
Motor capacity
81
Number of motor poles
84
Rated motor frequency
125
Terminal 2 frequency setting
(903)
gain frequency
126
Terminal 4 frequency setting
(905)
gain frequency
144
Speed setting switchover
Soft-PWM operation
240
selection
Induction
PM motor (setting in
motor
rotations per minute)
0 (initial value)
12
14
FM
CA
*1
120 Hz
Maximum
motor rotations
*2
60 Hz
per minute
Rated motor
60 Hz
50 Hz
rotations per
minute
Rated motor
Inverter rated
*8
current
current
Minimum
0.5 Hz
rotations per
minute
Minimum
5 Hz
rotations per
minute
Maximum
*1
120 Hz
motor rotations
*2
60 Hz
per minute
Rated motor
60 Hz
50 Hz
rotations per
minute
*5
*5
Short-time motor torque
120%
110%
0
0
Rated motor
60 Hz
50 Hz
rotations per
minute
Rated motor
Inverter rated
*8
current
current
*3
*3
0
210
240
Inverter
9999
*4
capacity
Number of
9999
*4
motor poles
Rated motor
rotations per
9999
*4
minute
Rated motor
60 Hz
50 Hz
rotations per
minute
Rated motor
60 Hz
50 Hz
rotations per
minute
Number of
4
motor poles +
100
1
0
Setting
PM motor (setting in
frequencies)
8009
112
114
9009
Maximum
motor
Maximum
Maximum
rotations
motor
motor
per
frequency
frequency
*6
minute
Rated motor
Pr.84
Pr.84
frequency
Rated motor
*8
current
Pr.84 ×
Minimum
Pr.84 ×
10%
frequency
10%
Pr.84 ×
Minimum
Pr.84 ×
10%
frequency
10%
Maximum
motor
frequency
Rated motor
Pr.84
Pr.84
frequency
Rated motor
Pr.84
Pr.84
frequency
Rated motor
Pr.859
Pr.859
*8
current
*3
*3
210
240
Inverter
*4
capacity
Number of
*4
motor poles
Rated motor
*4
frequency
Rated motor
Pr.84
Pr.84
frequency
Rated motor
Pr.84
Pr.84
frequency
Number of
Pr.81 +100
Pr.81
motor poles
Setting
increments
12, 14,
0, 112,
8109
8009,
114, 8109,
9109
9009
9109,
1 r/min 0.01 Hz
*6
1 r/min 0.01 Hz
*1
0.01 A
*2
0.1 A
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1 r/min 0.01 Hz
0.1%
1
1 r/min 0.01 Hz
*1
0.01 A
*2
0.1 A
1
*1
0.01 kW
*2
0.1 kW
1
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1
1
177
5. PARAMETERS
5.2 Control method
1
2
3
4
5
6
7
8
9
10

Hide quick links: