Mitsubishi Electric FR-F820-00046 Instruction Manual page 470

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

 Analog source (monitor item) selection
• Select the analog sources (monitor items) to be set to Pr.1027 to Pr.1034 from the following table.
Setting
Monitor item
value
1
Output frequency/speed
2
Output current
3
Output voltage
Frequency setting value/motor
5
speed setting
6
Running speed
7
Motor torque
8
Converter output voltage
*5
For manufacturer setting
9
Electronic thermal O/L relay load
10
factor
11
Output current peak value
Converter output voltage peak
12
value
13
Input power
14
Output power
17
Load meter
18
Motor excitation current
20
Cumulative energization time
23
Actual operation time
24
Motor load factor
34
Motor output
40
PLC function user monitor 1
41
PLC function user monitor 2
42
PLC function user monitor 3
52
PID set point
53
PID measured value
54
PID deviation
61
Motor thermal load factor
62
Inverter thermal load factor
64
PTC thermistor resistance
67
PID measured value 2
*6
Emergency drive status
68
69
PID input pressure value
81
BACnet reception status
82
BACnet token pass counter
*1
"*" shows a monitor item with a high-speed sampling cycle.
*2
The monitor items with a circle (○) represents that its monitor value can be indicated with minus sign.
*3
Indicates a criterion at 100% when the analog trigger is set.
*4
Refer to the full-scale value of terminal FM/CA, or AM
*5
The setting is available for the standard model.
*6
The setting is available for the standard model and the IP55 compatible model.
*7
Rated motor frequency × 120 / number of motor poles
*8
The reference current for the trigger level is as follows.
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
Model FR-F820-[]
0.75K 1.5K 2.2K 3.7K 5.5K 7.5K
Trigger level
3
5
8
11
reference current (A)
Trigger
Minus (-)
*1
level
*2
display
criterion
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
65535
65535
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
Pr.561
*4
65535
*4
65535
65535
(page
11K
15K 18.5K 22K
17.5
24
33
46
61
76
Setting
Monitor item
value
*3
83
BACnet valid APDU counter
BACnet communication error
84
counter
BACnet Terminal FM/CA output
85
level
86
BACnet terminal AM output level
87
Remote output value 1
88
Remote output value 2
89
Remote output value 3
90
Remote output value 4
91
PID manipulated amount
Second PID set point/deviation
92
input selection
93
Second PID measured value
94
Second PID deviation
95
Second PID measured value 2
96
Second PID manipulated amount ○
98
Control circuit temperature
201
*Output frequency
202
*U-phase output current
203
*V-phase output current
204
*W-phase output current
205
Converter output voltage
206
*Output current (all three phases)
207
*Excitation current (A)
208
*Torque current (A)
209
Terminal 2
210
Terminal 4
211
Terminal 1
212
*Excitation current (%)
213
*Torque current (%)
230
*Output frequency (signed)
231
*Motor speed (with sign)
232
*Speed command (with sign)
237
*Excitation current command
238
*Torque current command
297).
30K
37K
45K
55K
75K
90K 110K
90
115
145
175
215
288
Trigger
Minus (-)
*1
*2
display
criterion
65535
65535
100%
100%
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
Pr.84
*8
*8
*8
400 V/800 V
*8
*8
*8
100%
100%
100%
100%
100%
Pr.84
*7
*7
100%
100%
346
5. PARAMETERS
5.11 (A) Application parameters
1
level
*3
2
3
4
5
6
7
8
9
10
469