Pr.
Name
Subtraction starting
263
frequency
Power failure deceleration
266
time switchover frequency
374
Overspeed detection level
% setting reference
390
frequency
505
Speed setting reference
Current average value
557
monitor signal output
reference current
870
Speed detection hysteresis
Regeneration avoidance
885
compensation frequency
limit value
Energy saving monitor
893
reference (motor capacity)
C14
Terminal 1 gain frequency
(918)
(speed)
—: Not changed
*1
Initial value for the FR-F820-02330(55K) or lower and FR-A840-01160(55K) or lower.
*2
Initial value for the FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
*3
When Pr.71 Applied motor = "213, 214, 243, 244, 8093, 8094, 9093, or 9094", the Pr.71 setting is not changed.
*4
When a value other than "9999" is set, the set value is not changed.
*5
110% for SLD rating and 120% for LD rating (Refer to Pr.570 Multiple rating setting on
*6
Use Pr.702 Maximum motor frequency to set the maximum motor frequency or rotations per minute. When Pr.702 ="9999 (initial value)", the
setting of Pr.84 Rated motor frequency is used as the maximum motor frequency or rotations per minute.
*7
The setting value is converted from frequency to rotations per minute. (It differs according to the number of motor poles.)
*8
Refer to
page 615
NOTE
• When the motor parameter initialization is performed with the setting in units of rotations per minute (Pr.998 = "12, 14, 8009,
or 9009"), the parameters not listed in the table and the monitor items are also set and displayed in rotations per minute.
 IPM motor specification list
Rated motor frequency (rotations per minute)
Maximum motor frequency (rotations per minute)
Number of motor poles
Short-time motor torque
Minimum frequency (rotations per minute)
Speed detection hysteresis frequency (rotations
per minute)
Overspeed detection level frequency (rotations per
minute)
178
5. PARAMETERS
5.2 Control method
Induction
motor
0 (initial value)
FM
CA
60 Hz
50 Hz
60 Hz
50 Hz
9999
60 Hz
50 Hz
60 Hz
50 Hz
Inverter rated
current
0 Hz
6 Hz
Inverter rated
capacity
60 Hz
50 Hz
for the rated motor current of MM-EFS/MM-THE4.
MM-EFS 1500 r/min spec.
Item
75 Hz (1500 r/min)
112.5 Hz (2250 r/min)
6
110% for SLD rating, 120% for LD rating
7.5 Hz (150 r/min)
0.5 Hz (10 r/min)
122.5 Hz (2450 r/min)
Setting
PM motor (setting in
rotations per minute)
8009
12
14
9009
Rated motor
rotations per
Pr.84
minute
Rated motor
rotations per
Pr.84
minute
Maximum
Motor rotations
motor
per minute at
rotations
overspeed
per minute
detection level
*6*7
+ 10 Hz
Rated motor
rotations per
Pr.84
minute
Rated motor
Pr.84
frequency
Rated motor
Pr.859
*8
current
Motor rotations
per minute at
*7
0.5 Hz
speed detection
hysteresis
Minimum
Pr.84 ×
rotations per
10%
minute
Motor capacity (Pr.80)
Rated motor
rotations per
Pr.84
minute
MM-EFS 1500 r/min spec.
(15 kW or lower)
(18.5 to 55 kW))
100 Hz (1500 r/min)
150 Hz (2250 r/min)
8
10 Hz (150 r/min)
0.5 Hz (8 r/min)
160 Hz (2400 r/min)
PM motor (setting in
frequencies)
8109
112
114
9109
Rated motor
Pr.84
frequency
Rated motor
Pr.84
frequency
Maximum
Motor
motor
frequency at
frequency +
overspeed
*6
detection level
10 Hz
Rated motor
Pr.84
frequency
Rated motor
Pr.84
frequency
Rated motor
Pr.859
*8
current
Motor
frequency at
0.5 Hz
speed detection
hysteresis
Minimum
Pr.84 ×
frequency
10%
Rated motor
Pr.84
frequency
page
194.)
MM-THE4 (75 to 160 kW)
75 Hz (1500 r/min)
90 Hz (1800 r/min)
6
7.5 Hz (150 r/min)
0.5 Hz (10 r/min)
100 Hz (2000 r/min)
Setting
increments
12, 14,
0, 112,
8009,
114, 8109,
9009
9109,
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1 r/min 0.01 Hz
1 r/min 0.01 Hz
0.01 Hz
*1
0.01 A
*2
0.1 A
1 r/min 0.01 Hz
1 r/min 0.01 Hz
*1
0.01 kW
*2
0.1 kW
1 r/min 0.01 Hz