 Removal (FR-F840-04320(185K) or higher)
1.
Remove the fan cover fixing screws, and remove the fan cover.
2.
Disconnect the fan connector and remove the fan block.
3.
Remove the fan fixing screws, and remove the fan.
Fan connection
connector
*1
The number of cooling fans differs according to the inverter capacity.
 Installation (FR-F840-04320(185K) or higher)
1.
After confirming the orientation of the fan, install the fan so that the "AIR FLOW" arrow faces up.
AIR FLOW
<Fan side face>
2.
Install fans referring to the above figure.
NOTE
• Installing the fan in the opposite direction of air flow may shorten the inverter life.
• Ensure that the cables are not caught when the fan is installed.
• Switch OFF the power before starting the fan replacement work. To prevent an electric shock accident, keep the inverter with
its covers on during fans replacement since the inverter circuits are charged with voltage even after power OFF.
Fan *1
Fan block
3)
2)
7. PRECAUTIONS FOR MAINTENANCE AND INSPECTION
Fan cover
1)
7.1 Inspection item
1
2
3
4
5
6
7
8
9
10