Mitsubishi Electric FR-F820-00046 Instruction Manual page 357

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Signal
Setting
name
8
REX
10
X10
11
X11
12
X12
13
X13
14
X14
16
X16
18
X18
24
MRS
STP
25
(STOP)
28
X28
37
X37
38
PDI1
39
PDI2
40
PDI3
46
TRG
47
TRC
48
X48
50
SQ
51
X51
57
JOGF
58
JOGR
60
STF
61
STR
62
RES
64
X64
65
X65
66
X66
67
X67
70
X70
71
X71
72
X72
73
X73
77
X77
78
X78
79
X79
80
X80
81
PGT
84
X84
94
X94
95
X95
96
X96
97
X97
98
X98
9999
- - -
*1
When Pr.59 Remote function selection ≠ "0", functions of the RL, RM, and RH signals are changed as shown in the table.
*2
The OH signal is activated when the relay contact is open.
356
5. PARAMETERS
5.9 (T) Multi-function input terminal parameters
Function
15-speed selection (Combination with multi-speeds of RL, RM, and
RH)
Inverter run enable (FR-HC2/FR-CV/FR-CC2 connection)
FR-HC2/FR-CC2 connection, instantaneous power failure
detection
PU operation external interlock
External DC injection brake operation start
PID control valid
PU/External operation switchover (External operation with X16-ON) Pr.79, Pr.340
V/F switchover (V/F control with X18-ON)
Output stop
Electronic bypass function
Start self-holding selection
Start-time tuning start external input
Traverse function selection
PID multistage set point setting 1
PID multistage set point setting 2
PID multistage set point setting 3
Trace trigger input
Trace sampling start/end
Power failure stop external
Sequence start
Fault clear
JOG forward rotation command
JOG reverse rotation command
Forward rotation command (assignable to the STF terminal
(Pr.178) only)
Reverse rotation command (assignable to the STR terminal
(Pr.179) only)
Inverter reset
PID forward/reverse action switchover
PU/NET operation switchover (PU operation with X65-ON)
External/NET operation switchover (NET operation with X66-ON)
Command source switchover (command by Pr.338 or Pr.339
enabled with X67-ON)
DC feeding operation permission
*3
DC feeding cancel
PID P control switchover
Second PID P control switchover
Pre-charge end command
Second pre-charge end command
Second PID forward/reverse action switchover
Second PID control valid
PID gain tuning start/forced end
Emergency drive execution command
Control signal input for main circuit power supply MC
Converter unit fault input
Converter unit fault (E.OHT, E.CPU) input
Cleaning valid
Cleaning trigger
No function
*3
*3
Related parameter
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.30, Pr.599
Pr.30
Pr.79
Pr.10 to Pr.12
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.80, Pr.81, Pr.800
Pr.17
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.250
Pr.95
Pr.592 to Pr.597
Pr.1460 to Pr.1466
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.261 to Pr.266, Pr.294,
Pr.668
Pr.414
Pr.414
Pr.15, Pr.16
Pr.15, Pr.16
Pr.250
Pr.250
Pr.75
Pr.127 to Pr.134
Pr.79, Pr.340
Pr.79, Pr.340
Pr.338, Pr.339
Pr.30
Pr.30
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.760 to Pr.764
Pr.765 to Pr.769
Pr.753 to Pr.758
Pr.753 to Pr.758
Pr.1211 to Pr.1219
Pr.514, Pr.515, Pr.523,
Pr.524, Pr.1013
Pr.30, Pr.137, Pr.248, Pr.254
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.1469 to Pr.1479
- - - -
Refer to
page
249
539
539
228
535
401
228
169
357
387
359
382
396
401
465
465
458
462
462
248
248
359
359
188
401
228
228
239
539
539
401
401
425
425
401
401
417
263
393
387
398
- - - -