Mitsubishi Electric FR-F820-00046 Instruction Manual page 496

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Read/
Item
write
Parameter clear / All
Write
parameter clear
Read
Parameter
Write
Read
Link parameter
extended setting
Write
Read
Second parameter
changing (instruction
code HFF = 1, 9)
Write
Read/
Multi command
write
Model
Read
Capacity
Read
*1
Refer to
page 485
for data formats (A, A1, A2, B, C, C1, D, E, E1, E2, E3, F).
*2
Turning OFF the power supply while clearing parameters with H5A5A or H55AA returns the communication parameter settings to the initial
settings.
*3
Refer to the following calibration parameter list for details on the calibration parameters.
*4
The gain frequency can be also written using Pr.125 (instruction code: H99) or Pr.126 (instruction code: H9A).
NOTE
• Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
• For the instruction codes HFF, HEC, and HF3, their values once written are held, but cleared to zero when an inverter reset
or all clear is performed.
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
Example) When reading the C3 (Pr.902) and C6 (Pr.904) settings from the inverter of station No. 0.
Computer send data
a
ENQ 00 FF 0 01 7D
b
ENQ 00 EC 0 01 79
c
ENQ 00 5E 0 0A
d
ENQ 00 60 0 F6
To read/write C3 (Pr.902) or C6 (Pr.904) after inverter reset or parameter clear, execute from (a) again.
Instruction
code
All parameters return to initial values.
Whether to clear communication parameters or not can be selected
according to the data.
• Parameter clear
H9696: Parameters including communication parameters are cleared.
H5A5A: Parameters other than communication parameters are cleared.
• All parameter clear
H9966: Parameters including communication parameters are cleared.
HFC
H55AA: Parameters other than communication parameters are cleared.
For the details of whether or not to clear parameters, refer to
When a clear is performed with H9696 or H9966, communication related
parameter settings also return to the initial values. When resuming the
operation, set the parameters again.
Performing a clear will clear the instruction code HEC, HF3, and HFF
settings.
Only H9966 and H55AA (All parameter clear) are valid when a password is
registered (refer to
H00 to H63
Refer to the instruction code
values as required. When setting Pr.100 and later, the link parameter
extended setting must be set.
H80 to HE3
H7F
Parameter settings are switched according to the H00 to H0D settings.
For details of the settings, refer to the instruction code
HFF
H6C
When setting the calibration parameters
*4
H00: Frequency
HEC
H01: Parameter-set analog value
H02: Analog value input from terminal
Available for writing 2 commands, and monitoring 2 items for reading data.
HF0
(Refer to
page 497
The model name can be read in ASCII code.
"H20" (blank code) is set for blank area.
H7C
Example) FR-F840-1 (FM type):
H46, H52, H2D, H46, H38, H34, H30, H2D, H31, H20, H20 ... H20
The capacity in the inverter model can be read in ASCII code.
Data read is displayed in increments of 0.1 kW (rounded down to one decimal
H7D
place).
"H20" (blank code) is set for blank area.
Example) 0.75K: " 7" (H20, H20, H20, H20, H20, H37)
Inverter send data
ACK 00
ACK 00
STX 00 0000 ETX 20
STX 00 0000 ETX 20
Data description
page
198).
(page
638) and write and/or read parameter
*3
for details.)
"H01" is set in the extended link parameter.
"H01" is set in the second parameter changing.
C3 (Pr.902) is read. 0% is read.
C6 (Pr.904) is read. 0% is read.
5.12 (N) Communication operation parameters
Number of
data digits
(format)
*2
4 digits (A and
*2
C/D)
page
638.
4 digits (B and
E/D)
4 digits (A and
C/D)
2 digits (B and
E1/D)
(page
638).
2 digits (A1 and
C/D)
2 digits (B and
E1/D)
2 digits (A1 and
C/D)
10 digits (A2
and C1/D)
20 digits (B and
E3/D)
6 digits (B and
E2/D)
Description
5. PARAMETERS
1
*1
2
3
4
5
6
7
8
9
10
495