4.6.3

126 errors

126 error messages
Error code
Description
126.01
Line frequency outside operating range of
device.
126.02
No line frequency detected.
LVPS service check
Action
Step 1
Check if the power supply cable is properly connected
to the controller board.
Is it properly connected?
Step 2
1.
Turn off the printer.
2.
Remove the power cord.
3.
Measure the resistance between terminals A and
D of the power supply socket.
Is the resistance approximately 30 ohms?
bizhub 4700P/bizhub 4000P Service Manual
- 102 -
Action
Go to
LVPS service
Yes
Go to step 2.
Contact your next level of
support.
check.
No
Reseat the cables.
Replace the power
supply. See
Power supply
removal.