Ppds Emulation; Download Emuls; Safe Mode; Factory Defaults - Konica Minolta Bizhub 4700P Service Manual

Hide thumbs Also See for Bizhub 4700P:
Table of Contents

Advertisement

Available options:
On
Off
5.4.8

PPDS Emulation

The value of this option determines if a printer can recognize and use the PPDS data stream.
Available options:
Deactivate
Activate
5.4.9

Download Emuls

This appears only if at least one download emulator (DLE) is installed. The default setting is Disable. All
download emulators (DLEs) are reenabled automatically after two PORs.

5.4.10 Safe Mode

The settings for this menu item are On and Off (default).
When On, the printer runs in a special mode in which it attempts to continue offering as much
functionality as possible despite known issues.
For example, when On, if the duplex motor is nonfunctional, then the printer prints all jobs in simplex.

5.4.11 Factory Defaults

Warning—Potential Damage: This operation cannot be undone.
This setting enables a user to restore all of the printer settings to either the network settings (on network
models only) or to the base printer settings.
To restore Factory Default settings:
1. From the Configuration menu, navigate to Factory Defaults.
2. Select from the available options:
-
Restore Base—restores all non-critical base printer NVRAM settings.
-
Restore STD Net—restores all network NVRAM settings.
After this setting is changed, the device automatically performs a POR, and restores the appropriate
settings to their factory default values.

5.4.12 Energy Conserve

This setting controls which values appear on the Power Saver menu.
To change the setting:
1. From the Configuration menu, navigate to Energy Conserve.
bizhub 4700P/bizhub 4000P Service Manual