No Data Can Be Output To The Machine Or The Machine Does Not Operate Even Though Data Is Being Output; Misaligned Origins; Operate Even Though Data Is Being Output - Roland MDX-50 User Manual

Hide thumbs Also See for MDX-50:
Table of Contents

Advertisement

Machine/VPanel Problems
2
When the following screen is displayed, use the dial to select "Yes," and then press [ENTER].
The tool bur is released in its current position.
3
Open the cover, and then remove the tool bur.
4
When "Please hit [ENTER] key." is displayed on the built-in panel, press [ENTER].

No Data Can Be Output to the Machine or the Machine Does Not Operate Even Though Data Is Being Output

Have the origins been set at correct
positions?
Is the command set correct?

Misaligned Origins

Has a correct workpiece coordinate
system been selected?
Has EXOFS been set?
72
7. Troubleshooting
Check that the origins have been set correctly. If the origin loca-
tions are not correct, cutting at an unintended location or to the
wrong depth may occur.
P. 22 "Step 4 : Setting the XY Origin"
P. 24 "Step 5 : Setting the Z Origin (Using the Z0 Sensor)"
Check that a command set that is compatible with the application
software you are using has been selected. If the command set is
not compatible, errors may occur, the machine may not operate,
or unintended operations may occur.
P. 51 ""Machine" Tab"
In the NC program, there are six coordinate systems. Depending
on which coordinate system is used, the origin positions differ.
For example, if the NC program uses G55, it is necessary to set the
origins according to workpiece coordinate system G55.
"NC Code Reference Manual" (electronic-format manual)
EXOFS in the NC code mode has a function to shift the origin.
Set EXOFS to zero, and then set the origin again.
Procedure for setting EXOFS to zero
1 Select [MACHINE] from the display of the coordinate system
in VPanel.
2. Move the tool bur position to "X: 0," "Y: 0," and "Z: 0."
3. Select [EXOFS] for the [Setting Reference Point].
4. Select [Set X-, Y-, and Z-origins here] for [Setting Reference
Point], and then click [Set].