Machine/VPanel Problems

Operations Are Ignored

Is the cable connected?
Was the machine started according to
the correct procedure?
Is the front cover or the dust box cover
open?
Is the driver installed correctly?
Are multiple machines connected to a
single computer?
Is VPanel or the built-in panel display-
ing an error message?
Is operation paused?
Does VPanel recognize the machine?
Is the spindle belt damaged or discon-
nected?

Detection with the Z0 Sensor Fails

Are you using a thin tool bur?
Are you using a non-conductive tool
bur?
Is the Z0 sensor dirty?
Is the cable connected?
70
7. Troubleshooting
Connect the cable securely.
"Setup Guide" ("Connecting the Cables")
Simply switching on the main power switch does not enable
operation. Start the machine using the correct procedure.
"Setup Guide"
If the front cover or the dust cover is open, the machine will not
start cutting even if cutting data is received. Close all the covers.
If the connection to the computer is not made according to the
procedure described, the driver will not be installed correctly.
Check again to ensure that the connection was made using the
correct procedure.
"Setup Guide" ("Installing the Windows Driver")
VPanel cannot control multiple machines at the same time. Never
connect multiple instances of this machine to a single computer.
VPanel or the built-in panel displays a description of the error.
P. 80 "An Error Message Appears"
When the machine is paused, cutting stops and some operations
are restricted.
Cancel the paused state.
P. 4 "Operation Keys"
Verify that "Offline" is not displayed in VPanel.
P. 7 "Displaying VPanel"
Check inside the maintenance cover. If the spindle belt is dam-
aged, replace it.
P. 33 "Periodic Maintenance"
If you use a thin or non-conductive tool bur, you may not be able
to perform correct detections. Use the detection pin.
Clean away any grime on the Z0 sensor. Fouling due to buildup of
cutting waste or the like on this item may impede correct sensor
operation, making detection impossible.
Connect the cable securely.