Toshiba e-STUDIO2006 Service Manual page 307

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

* The larger the adjustment value is, the shorter the distance D becomes and the blank area
becomes narrower (approx. 0.54 mm/step).
[E] Primary scanning data laser writing start position at duplexing
Notes:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.  (Adjustment Mode)
(2)
[SETTINGS]  [USER FUNCTIONS]  Select [DRAWER]  Select [DRAWER1]
 Set the paper size to A3/LD.  [OK]  Set A3/LD for the paper in upper drawer.
(3)
[CANCEL]  [CANCEL]  [SETTINGS] (Return to code entry screen)
 [3]  [SETTINGS]  [START] (A grid pattern with 10 mm squares is printed out on both sides
of the paper.)
(4)
Check the grid pattern printed on the reverse side of test chart and measure the distance E from
the left edge of the paper to the 6th line of the grid pattern.
(5)
Check if the distance E is within 52±0.5 mm.
(6)
If not, use the following procedure to change values and measure the distance E again.
(Adjustment Mode)  (Key in code [4019])  [START]  [0]  [START]
 (Key in a value (acceptable values: 0 to 255))
 [OK] (Stored in memory)
 Press [3]  [SETTINGS]  [START].  (A grid pattern is printed out on both sides of the
paper.)
* The larger the adjustment value is, the longer the distance E becomes (approx. 0.05 mm/
step).
(7)
After the adjustment for the code 4019-0 is completed, apply the same adjustment value for the
code 4019-1.
(Adjustment Mode)  (Key in the code [4019])  [START]  [1]  [START]
 (Key in the same value in the step 6 above)  Press [OK] (Stored in memory).
<Adjustment procedure summarization for A to E>
When the value is 1.
[0] [5] [Power ON]  [1] ([3](05-4062, 4019) for duplexing)  [SETTINGS]  Select [DRAWER1] 
[START]
A;
05-4001 (Upper drawer, A3/LD)
B: [B-1]
05-4006 (Upper drawer, A3/LD)
05-4018-1 (Lower drawer, A3/LD)
[B-2]
05-4018-2 (PFP1, A3/LD)
05-4018-3 (PFP2, A3/LD)
05-4018-4 (Bypass feed, A3/LD)
C:
05-4009 (Upper drawer, A3/LD)
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
 200±0.5 mm (0.1 mm/step)
 52±0.5 mm (0.04 mm/step)
 Key in the same value for 05-4005.
 52±0.5 mm (0.04 mm/step)
 52±0.5 mm (0.04 mm/step)
 52±0.5 mm (0.04 mm/step)
 52±0.5 mm (0.04 mm/step)
 200±0.5 mm (0.14 mm/step)