NT30/30C Status Control
S NT-series Support Tool Settings
Make the following setting using the NT-series Support Tool.
Allocated Word for the PT Status Control Area: IR/CIO 0100
S PC Program
Include the following in the PC ladder program.
09002
09003
09003
09003
09002
S Program Operation
(1) The PT status control bits are set as shown below when IR/CIO 09002 turns
OFF. This command block is not executed when IR/CIO 09003 is ON.
Screen display (bit 15)
Continuous buzzer (bit 13)
The NT30/30C continuous buzzer sounds.
(2) The PT status control bits are set as shown below when IR/CIO 09003 turns
OFF.
Screen display (bit 15)
Short intermittent buzzer (bit 12)
The NT30/30C short intermittent buzzer sounds.
(3) The PT status control bits are set as shown below when both IR/CIO 09002
and IR/CIO 09003 turn ON.
Continuous buzzer (bit 13)
Short intermittent buzzer (bit 12)
The NT30/30C buzzer stops.
@MOV(21)
Display the screen, sound continuous buzzer
#A000
Word for PT status control
103
@MOV(21)
Display the screen, sound short intermittent
#9000
buzzer
103
Word for PT status control
@ANDW(34)
Word for PT status control
103
Only continuous and short intermittent
#CFFF
buzzers are 0
103
Word for PT status control
1 (Performed)
1 (Sounded)
1 (Performed)
1 (Sounded)
0 (Not sounded)
0 (Not sounded)