Numeral Setting

4-8-6 Setting Items for Numeral Setting

Items to be Set
Restrictions and Additions when Creating the Thumb Wheel Type
170
For the numeral setting, the following items are set when being created with the
NT-series Support Tool. However, for numeral setting of thumb wheel type, there
are some restrictions on the setting of several items.
S Numeral Memory Table Entry To Access
The number of the numeral memory table entry is specified to register the nu-
meric values entered for the numeral setting.
S Number of Digits of Numeric Value Entered
The number of digits of numeric value entered is specified. Up to 8-digit can be
specified by figuring out a sum of the number of digits of both integer part and
decimal fraction. However, when displaying a sign, the number of negative
numbers is limited to a maximum of 7-digit.
S Upper/Lower Limit
Upper limit and lower limit are set separately. A maximum of 8-digit numeric
value (up to 7-digit for negative numbers) can be set.
When the upper limit value or lower limit value is negative, set F as the eighth
digit.
Example: When the upper limit value or lower limit value is –123, set
F0000123.
S Display Attribute
The same attributes as the numeral display are set. For details, refer to the Nu-
merals that Can Be Displayed (page 139).
For numeral setting for thumb wheel type, there are the following restrictions and
additions when setting the items.
S Number of Digits of Positive Numbers To Be Entered with a Sign Dis-
played
For the thumb wheel type, with a sign displayed, the maximum number for the
total number of digits in the integral portion and the decimal portion of positive
numbers to be entered is 7.
S Display Size
There are only three kinds of size that can be specified. Size is specified by the
touch switch size of the increment/decrement (+, –) keys. Display size is se-
lected out of three size: minimum unit of touch switch (20 dots by 20 dots), 1 x 1
(small), 2 x 2 (medium), 3 x 3 (large). Entire size of the numeral setting input
column is specified by the touch switch size just specified.
S Shape (End Plate)
Either of the two kinds of shape as shown below can be set. Decoration (end
plate) at both ends of the numeral setting input column differs.
With End Plate
1 2 3 4 5 6 7 8
Section
Without End Late
1 2 3 4 5 6 7 8
4-8