Omron NT30 Operation Manual page 187

Programmable terminal
Hide thumbs Also See for NT30:
Table of Contents

Advertisement

Pop-Up Window Function
178
Numeral setting input
Temporary input field (displays data being input)
1 2 3 4 5 6
0
555 . 44
7 8 9 ↑
– 4 1. 8
4 5 6 ↓
0
0 0 2 .7 1
1 2 3 ±
0 . ENT
Current setting
Window
It is possible to display a window simultaneously with a cursor movement.
For details, see Opening Windows with the Cursor Moving Keys (page 177).
(2) If the window in which the temporary input field is registered is not displayed,
open it (this could also be done prior to step (1)). For the method for opening
the window, see Opening and Closing Windows (page 176).
The temporary input field displays the contents of the actual input field at that
point in time. The display of the temporary input field is governed by the fol-
lowing attributes:
• Attributes determined by the settings for the temporary input field:
Character font, scale, display attribute, smoothing, character color, back-
ground color
• Attributes determined by the settings for the actual input field on the base
screen:
Numbers of integer and decimal fraction digits, upper limit value, lower limit
value, decimal/hexadecimal, zero suppress, sign display.
The cursor frame of the temporary input field is always displayed.
(3) Input the numerical value or character string. The method is the same as
that normally used to input numerical values and character strings. See En-
tering the Numeral Values (page 167), or How to Enter the Character Strings
(page 172).
The numerical value or character string is input into the temporary input
field.
(4) The input numerical value of character string is written to the input field on
the base screen on confirming it by pressing the ENT key or the return key
(
), and the contents of the corresponding numeral/character string
memory table entry are changed accordingly (notification to the PC also
takes place at this time). On confirming by pressing the ENT key, the cursor
moves to the next input field on the base screen.
If the input value is outside the range delimited by the upper and lower limit
values, the original value is redisplayed.
Note also that if the actual input field on the base screen is changed before
input is confirmed, the input data will be destroyed. The input data will also
be destroyed if the window is closed or the screen is switched before con-
firmation.