Mitsubishi Electric FR-A820-00046 Instruction Manual page 655

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Pr. 71
5
15
6
16
Tab. 5-175: Setting of parameter Pr. 71 and Pr. 450 (2)
The setting is available for FR-A820-00630(11K) or lower.
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
The same operation is performed for both settings.
NOTES
Regardless of the Pr. 71 (Pr. 450) setting, offline auto tuning can be performed according to Pr. 96
(Pr. 463) "Auto tuning setting/status". (Refer to page 5-72 for offline auto tuning.)
FR-A800
Pr.
Motor
450
Standard motor
Constant-torque motor
Standard motor
Constant-torque motor
9999
(initial
No second applied motor
value)
Constant value range when
performing offline auto tuning
(increment)
Pr. 82 (Pr. 455) and Pr. 859
(Pr. 860)
0 to 500 A, 9999 (0.01 A)
0 to 3600 A, 9999 (0.1 A)
Pr. 90 (Pr. 458) and
Pr. 91(Pr. 459)
0 to 50 Ω, 9999 (0.001 Ω)
0 to 400 mΩ, 9999
(0.01 mΩ)
Pr. 92 (Pr. 460) and Pr. 93
(Pr. 461)
0 to 50 Ω, 9999 (0.001 Ω)
0 to 3600 mΩ, 9999
(0.1 mΩ)
Pr. 94 (Pr. 462)
0 to 500 Ω, 9999 (0.01 Ω)
0 to 100 Ω, 9999 (0.01 Ω)
(C) Motor constant parameters
Operational characteristic
of the electronic thermal O/L
relay
Stand-
Constant
-torque
ard
5 - 453
PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents