Mitsubishi Electric FR-A820-00046 Instruction Manual page 423

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
PID monitor indicator setting (Pr. 999 = "1 or 2")
Pr.
759
1142
774
775
776
C42 (934)
C44 (935)
1136
1138
Tab. 5-82:
Enabled when the FR-LU08 (-01) is used.
Enabled when the FR-PU07 is used.
Enabled when the FR-PU07-01 is used.
● 3-line monitor setting
On the operation panel or parameter unit, the 3-line monitor is used as the first monitor.
● Extended direct setting
Pressing the FUNC key of the FR-PU07-01 displays the extended direct setting screen. The PID
action set point can be directly set regardless of the operation mode or Pr. 77 "Parameter write
selection" setting.
Pressing the FUNC key on the extended direct setting screen displays the function menu.
Extended direct setting
Extended direct setting 1
Extended direct setting 2
Tab. 5-83:Parameter to be set by extended direct setting
● Dedicated parameter list function
Pressing the PrSET key of the FR-PU07-01 displays the dedicated parameter list. Parameters that
need to be set first for the PID extended display setting are listed.
Dedicated parameter list
No. 1
No. 2
No. 3
Tab. 5-84:Parameter to be set by dedicated parameter list
NOTE
The display of parameters other than the above may be changed due to changes in C42 or C44.
Set the PID monitor indicator before changing the settings of other parameters.
FR-A800
Name
PID unit selection
Second PID unit selection
Operation panel monitor selection 1
Operation panel monitor selection 2
Operation panel monitor selection 3
PID display bias coefficient
PID display gain coefficient
Second PID display bias coefficient
Second PID display gain coefficient
3-step monitor setting
Extended direct setting
Dedicated parameter list function
GOT initial setting (PU connector)
(E) Environment setting parameters
Initial
Pr. 999 = "1"
value
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
Disabled
Enabled
Disabled
Disabled
Parameter to be set
Pr. 133 PID action set point
Pr. 755 Second PID action set point
Parameter to be set
Pr. 999 Automatic parameter setting
Pr. 934 PID display bias coefficient
Pr. 935 PID display gain coefficient
Pr. 999 = "2"
Refer to page
4
5-562
4
52
53
5-344
54
0
100
5-562
0
100
Enabled
Enabled
5 - 221