Parameters
Pr.
Name
Pr. 998
374
Overspeed detection level
Frequency for maximum
386
input pulse
505
Speed setting reference
Current average value
557
monitor signal output
reference current
820
Speed control P gain 1
Speed control integral
821
time 1
Torque control P gain 1
824
(current loop proportional
gain)
Torque control integral time
825
1 (current loop integral
time)
870
Speed detection hysteresis
Regeneration avoidance
885
compensation frequency
limit value
Energy saving monitor
893
reference (motor capacity)
C14
Terminal 1 gain frequency
(918)
(speed)
Per-unit speed control
1121
reference frequency
⎯: Not changed
Tab. 5-27:
IPM parameter initialization list (2)
Initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
Initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) and higher.
Setting Pr. 71 "Applied motor" = "333, 334, 8093, 8094, 9093, or 9094" does not change the Pr. 71
setting.
When a value other than "9999" is set, the set value is not changed.
200 r/min when Pr. 788 "Low speed range torque characteristic selection" = "0".
13.33 Hz when Pr. 788 "Low speed range torque characteristic selection" = "0".
110% for SLD, 120% for LD, 150% for ND, and 200% for HD
(Refer to Pr. 570 "Multiple rating setting" page 5-209.)
The Pr. 702 "Maximum motor frequency" is used as the maximum motor frequency (rotations per
minute). When Pr. 702 = "9999 (initial value)", the Pr. 84 "Rated motor frequency" is used as the
maximum motor frequency (rotations per minute).
The setting value is converted from frequency to rotations per minute. (The value after the conversion
differs according to the number of motor poles.)
FR-A800
Induction
PM motor
motor
(rotations per minute)
0
(initial value)
3003
(MM-CF)
FM
CA
9999
3150 r/min
60 Hz
50 Hz
2000 r/min
60 Hz
50 Hz
133.33 Hz
Rated motor
Inverter rated
current
current
(Refer to
page 8-8.)
60%
0.333 s
100%
5 ms
0 Hz
8 r/min
6 Hz
200 r/min
Inverter rated
capacity
60 Hz
50 Hz
2000 r/min
120 Hz
60 Hz
Setting
PM motor (frequency)
8009
9009
3103
(other than
(MM-CF)
MM-CF)
Maximum
motor
rotations per
210 Hz
minute
+10 Hz
Pr. 84
133.33 Hz
Pr. 84
133.33 Hz
Rated motor
current
Pr. 859
(Refer to
page 8-8.)
30%
0.333 s
100%
20 ms
0.5 Hz
0.5 Hz
Pr. 84 × 10%
13.33 Hz
Motor capacity (Pr. 80)
Pr. 84
133.33 Hz
Maximum
motor
200 Hz
rotations per
minute
Control method
Setting increments
8109
3003,
0, 3103,
9109
8009,
(other than
9009
MM-CF)
Maximum
motor
1 r/min
0.01 Hz
frequency
+10 Hz
Pr. 84
1 r/min
0.01 Hz
Pr. 84
0.01 Hz
0.01 A
Pr. 859
0.1 A
1%
0.001 s
1%
0.1 ms
1 r/min
0.01 Hz
Pr. 84 × 10%
1 r/min
0.01 Hz
0.01 kW
0.1 kW
Pr. 84
1 r/min
0.01 Hz
Maximum
motor
1 r/min
0.01 Hz
frequency
8109,
9109
5 - 79