Parameters
Pr.
1108
M052
Monitor description list (Pr. 52, Pr. 774 to Pr. 776, Pr. 992)
● Set the monitor to be displayed on the operation panel and parameter unit in Pr. 52, Pr. 774 to Pr.
776, Pr. 992.
● Refer to the following table and set the monitor to be displayed. (The monitor marked
be selected. "
Types of
monitor
Output
frequency/
speed
Output current
Output voltage
Fault display
Frequency
setting value/
speed setting
Running speed
Motor torque
Converter
output voltage
Regenerative
brake duty
Electronic
thermal O/L
relay load factor
Output current
peak value
Converter
output voltage
peak value
Input power
Output power
Tab. 5-130: Monitor description list (1)
FR-A800
Name
Excitation current monitor filter
" in the [Minus (-) display] indicates a display with a minus sign.)
Pr. 52,
Unit
Pr. 774 to Pr. 776,
Pr. 992
0.01 Hz/1
1/0/100
0.01 A/
2/0/100
0.1 A
0.1 V
3/0/100
0/100
0.01 Hz/1
5
1 (r/min)
6
0.1%
7
0.1 V
8
0.1%
9
0.1%
10
0.01 A/
11
0.1 A
0.1 V
12
0.01 kW/
13
0.1 kW
0.01 kW/
14
0.1 kW
(M) Monitor display and monitor output signal
Initial value
Setting range
0 to 5 s
9999
9999
RS-485
communica-
Modbus®
tion dedicat-
RTU real
ed monitor
time
(hexadeci-
monitor
mal)
H01
40201
H02
40202
H03
40203
H05
40205
H06
40206
H07
40207
H08
40208
H09
40209
H0A
40210
H0B
40211
H0C
40212
H0D
40213
H0E
40214
Description
The filter time constant is selectable
for monitoring of the motor
excitation current. A larger setting
results in slower response.
0.3 s filter
Minus (-)
Description
display
Displays the inverter output
frequency.
Displays the inverter output
current effective value.
Displays the inverter output
voltage.
Displays 8 past faults
individually.
Displays the set frequency
Displays the motor speed (by the
Pr. 37, Pr. 144 settings).
(Refer to page 5-341)
The actual motor speed by
encoder signal is used during
encoder feedback control and
vector control.
Displays motor torque as a
percentage (0% under V/F
control), considering the rated
torque as 100%.
Displays the DC bus voltage
value.
Brake duty set in Pr. 30 and Pr. 70
Displays the motor thermal
cumulative value, considering
the thermal operation level as
100%.
Saves and displays the output
current monitor peak value.
(Cleared with each start.)
Saves and displays the DC bus
voltage peak value.
(Cleared with each start.)
Displays the power at the
inverter input side.
Displays the power at the
inverter output side.
cannot
5 - 345