Check first when you have a trouble
6.6.3

Inverter generates abnormal noise

Check
points
Fan
6.6.4

Motor generates heat abnormally

Check
points
Motor
Main
circuit
Parameter
setting
6.6.5

Motor rotates in the opposite direction

Check
points
Main
circuit
Input
signal
Input
signal
Parameter
setting
6 - 44
Possible cause
Fan cover was not correctly installed when a
cooling fan was replaced.
Possible cause
Motor fan is not working
(Dust is accumulated.)
Phase to phase insulation of the motor is
insufficient.
The inverter output voltage (U, V, W) are
unbalanced.
Pr. 71 "Applied motor" setting is incorrect.
Motor current is large.
Possible cause
Phase sequence of output terminals U, V
and W is incorrect.
The start signals (forward rotation, reverse
rotation) are connected improperly.
The polarity of the frequency command is
negative during the polarity reversible
operation set by Pr. 73 "Analog input
selection".
Torque command is negative during torque
control under vector control.
Countermeasure
Install a fan cover correctly.
Countermeasure
Clean the motor fan.
Improve the environment.
Check the insulation of the motor.
Check the output voltage of the inverter.
Check the insulation of the motor.
Check the Pr. 71 "Applied motor" setting.
Refer to "6.6.11 Motor current is too large".
Countermeasure
Connect phase sequence of the output cables
(terminal U, V, W) to the motor correctly.
Check the wiring.
(STF: forward rotation, STR: reverse rotation)
Check the polarity of the frequency command.
Check the torque command value.
Protective functions
Refer to
page
7-7
Refer to
page
7-7
5-451
6-47
Refer to
page
2-34
2-44,
5-447
5-406
5-138

Hide quick links: