Setting Up The Server To Recognize The Logical Units; For Direct Connection - Fujitsu ETERNUS DX Configuration Manual

Fibre channel for oracle solaris driver settings for non-fujitsu fibre channel cards
Hide thumbs Also See for ETERNUS DX:
Table of Contents

Advertisement

Chapter 1
Operations When Using Oracle Fibre Channel Cards
1.4

Setting Up the Server to Recognize the Logical Units

For the ETERNUS DX/AF
The parameter to be specified for the command queue depth is determined by the CPU which is in-
stalled in the server to be connected.
For SPARC
-
Specify the command queue depth for the "ssd_max_throttle" parameter.
Add this parameter if it does not exist.
Example:
set ssd:ssd_max_throttle = 20
For x86
-
Specify the command queue depth for the "sd_max_throttle" parameter.
Add this parameter if it does not exist.
Example:
set sd:sd_max_throttle = 20
2
After editing the configuration file, save it.
3
After the setting is complete, check the configuration file for incorrect settings.
4
Reboot the server.
# /usr/sbin/shutdown -y -g0 -i6
1.4
Setting Up the Server to Recognize the Logical Units
Make the server recognize the ETERNUS DX/AF logical units using the ssd driver.
If Oracle Fibre Channel cards are used, the logical unit recognition method will depend on the ETERNUS
DX/AF storage systems to server connection topology. There are two possible connection topologies: direct
connection and switch connection.
1.4.1

For Direct Connection

Confirm that the logical units have been correctly recognized by servers.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
17
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0