Fujitsu ETERNUS DX Configuration Manual page 32

Fibre channel for oracle solaris driver settings for non-fujitsu fibre channel cards
Hide thumbs Also See for ETERNUS DX:
Table of Contents

Advertisement

Chapter 2
Setup Procedure for Emulex Fibre Channel Cards
2.3
Setting Up the Server
1
Check the instance names.
"lpfc + instance number" is the format used to represent Fibre Channel card instance names.
The instance number that corresponds to the physical path in which the Fibre Channel card is installed
is stored in the "/etc/path_to_inst" file at the Fibre Channel card driver installation.
Extract necessary parts using the "grep" command.
# grep "lpfc" /etc/path_to_inst
Example:
"/pci@9,600000/lpfc@1" 0 "lpfc"
"/pci@9,600000/lpfc@2" 1 "lpfc"
The underlined portion "/pci@9,600000/lpfc@2" indicates the physical path name, and "1" indicates the
instance number.
"lpfc0" is the instance name of the "/pci@9,600000/lpfc@1" path Fibre Channel card. "lpfc1" is the
instance name of the "/pci@9,600000/lpfc@2" path Fibre Channel card.
2
Enter the results in "Instance name" and "Physical path name" columns of the "WWN instance manage-
ment table for the server".
Example:
Physical slot name
3
Check the WWN of each Fibre Channel card.
Open the "/var/adm/messages" file to identify the WWNs.
(The "WWPN" value in the 3rd line is a WWN, with an instance name of "lpfc0".)
(The "WWPN" value in the 11th line is a WWN, with an instance name of "lpfc1".)
Nov 17 10:27:40 t5220.i14y-ux.com lpfc: [ID 129691 kern.notice] NOTICE: lpfc0: Firmware Rev 1.10A5 (U2D1.10A5)
Nov 17 10:27:40 t5220.i14y-ux.com lpfc: [ID 651404 kern.notice] NOTICE: lpfc0: Fcode Rev 3.10a3
Nov 17 10:27:40 t5220.i14y-ux.com lpfc: [ID 507530 kern.notice] NOTICE: lpfc0: WWPN:10:00:00:00:c9:36:60:46
WWNN:20:00:00:00:c9:36:60:46 MSIX:2
Nov 17 10:27:40 t5220.i14y-ux.com lpfc: [ID 396126 kern.info] NOTICE: Device Path for interface lpfc0:
Nov 17 10:27:40 t5220.i14y-ux.com pxb_plx: [ID 370704 kern.info] PCI-device: lpfc@0,1, lpfc0
Nov 17 10:27:40 t5220.i14y-ux.com genunix: [ID 936769 kern.info] lpfc0 is /pci@0/pci@0/pci @8/pci@0/pci@9/lpfc@0,1
Nov 17 10:26:24 t5220.i14y-ux.com lpfc: [ID 129691 kern.notice] NOTICE: lpfc1: Firmware Rev 1.10A5 (U2D1.10A5)
Nov 17 10:26:24 t5220.i14y-ux.com lpfc: [ID 651404 kern.notice] NOTICE: lpfc1: Fcode Rev 3.10a3
Nov 17 10:26:24 t5220.i14y-ux.com lpfc: [ID 507530 kern.notice] NOTICE: lpfc1: WWPN:10:00:00:00:c9:36:5d:9e
WWNN:20:00:00:00:c9:36:5d:9e MSIX:2
Nov 17 10:26:24 t5220.i14y-ux.com lpfc: [ID 396126 kern.info] NOTICE: Device Path for interface lpfc1:
Nov 17 10:26:24 t5220.i14y-ux.com pxb_plx: [ID 370704 kern.info] PCI-device: lpfc@0,1, lpfc1
Nov 17 10:26:24 t5220.i14y-ux.com genunix: [ID 936769 kern.info] lpfc1 is /pci@0/pci@0/pci@8/pci@0/pci@1/lpfc@0,1
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
WWN
Instance name
lpfc0
lpfc1
Instance name
32
Copyright 2017 FUJITSU LIMITED
Physical path name
/pci@9,600000/lpfc@1
/pci@9,600000/lpfc@2
WWN
P3AM-6312-18ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus af

Table of Contents