Fujitsu ETERNUS DX Configuration Manual page 71

Fibre channel for oracle solaris driver settings for non-fujitsu fibre channel cards
Hide thumbs Also See for ETERNUS DX:
Table of Contents

Advertisement

Chapter 3
Setup Procedure for QLogic Fibre Channel Cards
3.5
Required Driver Parameters
hba0-port-down-retry-count=8;
hba1-port-down-retry-count=8;
# Amount of time to delay between port down retries.
#
Range: 0 - 255 seconds
hba0-port-down-retry-delay=0;
hba1-port-down-retry-delay=0;
# Maximum number of LUNs to scan for, if a device does not
# support SCSI Report LUNs command.
#
Range: 1 - 256
hba0-maximum-luns-per-target=8;
hba1-maximum-luns-per-target=8;
# Connection options.
#
0 = loop only
#
1 = point-to-point only
#
2 = loop preferred, otherwise point-to-point
hba0-connection-options=1;
hba1-connection-options=1;
# Enable FCP 2 Error Recovery support enable/disable.
#
0 = disable, 1 = enabled
hba0-fc-tape=0;
hba1-fc-tape=0;
# Fibre Channel Data Rate Option.
#
0 = 1 gigabit/second
#
1 = 2 gigabit/second
#
2 = Auto-negotiate
#
3 = 4 gigabit/second
#
4 = 8 gigabit/second
hba0-fc-data-rate=4;
hba1-fc-data-rate=4;
# PCI latency timer.
#
Range: 0x8 - 0xF8 -- must be a multiple of 8
hba0-pci-latency-timer=0x40;
hba1-pci-latency-timer=0x40;
# During link down conditions enable/disable the reporting of
# errors.
#
0 = disabled, 1 = enable
hba0-link-down-error=1;
hba1-link-down-error=1;
# Amount of time to wait for loop to come up after it has gone down
# before reporting I/O errors.
#
Range: 0 - 240 seconds
hba0-link-down-timeout=60;
hba1-link-down-timeout=60;
# Persistent binding only option.
#
0 = Reports to OS discovery of binded and non-binded devices
#
1 = Reports to OS discovery of persistent binded devices only
# Note: This entry is ignored when qla-mpconfig parameter is found.
hba0-persistent-binding-configuration=0;
hba1-persistent-binding-configuration=0;
# Persistent binding by port ID.
#
0 = disabled, 1 = enable
hba0-persistent-binding-by-port-ID=0;
hba1-persistent-binding-by-port-ID=0;
# Fast error reporting to Solaris, enabled/disabled.
#
0 = disabled, 1 = enable
hba0-fast-error-reporting=0;
hba1-fast-error-reporting=0;
# Extended logging level.
#
Range: 0 - 255, 0 = disabled
hba0-extended-logging=0;
hba1-extended-logging=0;
# Number of times to retry a SCSI queue full error.
#
Range: 0 - 255
hba0-queue-full-retry-count=16;
hba1-queue-full-retry-count=16;
# Amount of time to delay after a SCSI queue full error before
# starting any new I/O commands.
#
Range: 0 - 255 seconds
hba0-queue-full-retry-delay=2;
hba1-queue-full-retry-delay=2;
# Enable DH-CHAP security protocols.
#
0 = disabled, 1 = enable
hba0-security-protocols=0;
hba1-security-protocols=0;
# FDMI support.
#
0 = disabled, 1 = enable
hba0-FDMI-support=0;
hba1-FDMI-support=0;
# Use target/lun VPD data for failover configuration support.
#
0 = disabled, 1 = enable
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For direct connections, set to "0".
For both direct connections and switch connections, add these settings.
For both direct connections and switch connections,
add these settings.
Each value indicates the following meaning:
0 --> 1G fixed
1 --> 2G fixed
2 --> Auto (default)
3 --> 4G fixed
4 --> 8G fixed
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch
connections, add these settings.
For both direct connections and switch
connections, add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
For both direct connections and switch connections,
add these settings.
71
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus af

Table of Contents