ETL600 System Test Report
Test
No.
Test procedure
B.10.3
Remote subscriber. At
remote equ. is
Pax 2-Wire
Test Ringer: Feed
ringing voltage (25 VAC,
25 Hz, R = 2.2 kΩ) into
remote PAX 2-Wire
Measure Output level.
Feed 800 Hz with
configured input level of
remote PAX.(Def.:
-7.0 dBm)
B.10.4
Remote subscriber. At
remote equ. is
Pax 4-wire
Test Ringer:
Activate M-WIRE of
remote Pax 4-wire.
Measure Output level.
Feed 800 Hz with
configured input level of
remote PAX.(Def.:
-3.5 dBm)
B.10.5
Pax 2-wire
Measure Output level.
Feed 800 Hz with
configured input level of
remote subscriber.(Def.:
0.0 dBm)
PAX-BLOCKING normal Measure at terminal,
PAX-BLOCKING
blocked
Switch off remote equ.,
wait about 30 sec.
© ABB Switzerland Ltd
Revision:
_
Test point
Mark if configured:
Feed into rem. equ. at
terminal, telephony
8a-8b
Feed into rem. equ. at
terminal, telephony
8a-8b
Measure at terminal,
telephony 0a-0b
Mark if configured:
Activate at Remote
equ. at terminal,
telephony 4a-4b
Feed into rem. equ. at
terminal, telephony
1a-1b
Measure at terminal,
telephony 0a-0b
Mark if configured:
Feed into rem. equ. at
terminal, telephony
0a-0b
Measure at terminal,
telephony 8a-8b
telephony 6a-6b, 6b-7a
Measure at terminal,
telephony 6a-6b, 6b-7a
Language:
Page:
EN
B6/B11
Permissible
value
Units
Subscriber must
ring
Configured Output
dBm
(600 Ω)
level ±1 dB
(Def.: -7.0 dBm)
Subscriber must
ring
Configured Output
dBm
(600 Ω)
level ±1 dB
(Def.: -7.0 dBm)
Configured Output
dBm
(600 Ω)
level ±1 dB
(Def.: 0.0 dBm)
6a-6b is open
6b-7a is closed
6a-6b is closed
6b-7a is open
HE
Test
result
N11
N22
N54
[ ]
[ ]
N11
N22
N54
[ ]
[ ]
N11: ___________
N22: ___________
N54: ___________
N11
N22
N54
[ ]
[ ]
N11
N22
N54
[ ]
[ ]
N11: ___________
N22: ___________
N54: ___________
N11
N22
N54
[ ]
[ ]
N11: ___________
N22: ___________
N54: ___________
N11
N22
N54
[ ]
[ ]
N11
N22
N54
[ ]
[ ]
Form 1KHW001493-EN
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
Rev. A