System Power Level L 0 [Dbm0]; Relative Power Level L Rel [Dbr]; Level Measurements - ABB ETL600 Instruction Manual

Digital power line carrier system
Table of Contents

Advertisement

ABB Switzerland Ltd
Example:
The power level at the 75 Ohm RF output of a PLC equipment is 40 dBm. What is the
voltage level L
5.2.7.

System power level L 0 [dBm0]

The system power level L
signal in a system regardless of the measuring point.
The dBm0 value defines by how many dB a signal is greater or less
than a reference signal, which thus is defined to have an system
power level of 0 dBm0. In the ETL, the reference signal is the average
nominal speech level at the two-wire output.
The system power level is a property of the signal and doesn't depend
on the measuring point. As such, it is used to define signal levels
without reference to a specific measuring point.
Each signal has specific average (dBm0), peak (dBm0 peak) and peak
envelope (dBm0 PE) system power levels.
5.2.8.

Relative power level L rel [dBr]

The relative power level L rel defines the signal levels at various points
of a system without reference to the applied signals.
The dBr value is the difference between absolute power level L and
system power level L
The relative power level is a property of the measuring point and
doesn't depend on the signal.
5.2.9.

Level measurements

Test sockets allow the measurement of some internal signal levels. In
case of decoupled test sockets, this is possible without influence on
the signals being measured,. However, the voltage level at the test
socket depends on the input impedance of the measuring set being
used. Therefore, this impedance must be specified for each test socket
of the equipment. For the ETL600, input impedances ≥ 5 kOhms (also
referred to as "infinite") or 50 Ohms are specified.
The decoupling circuitry of the test socket normally amplifies or
attenuates the level to be measured by an amount of A
to bring it in a range suitable for measurement. The power level L of
the internal signal to be measured can then be calculated from the
voltage level L
5-6
1KHW001489-EN
?
U
=
+
L
40
dBm
10
u
=
.
31
dBu
is used in order to define the level of a
0
:
0
[
]
[
=
L
dBr
L
dBm
rel
at the test socket via the relationship
u|ts
November 2005
75
Ohm
⎜ ⎜
⎟ ⎟
log
600
Ohm
]
[
]
L
dBm
0
.
0
Configuration and Set-up
ETL600
(17)
[dB] in order
ts

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents