Furuno FEA-2107-BB Installation Manual page 32

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107-BB:
Table of Contents

Advertisement

2.3.2
Serial data channels in general
An example of serial channel (here channel 1)
RX1+
Input terminals for electrical standards IEC 61162-1, RS-232 and RS-422.
"RX+" and "RX-" may be defined as "RX-A" and "RX-B" in IEC 61162-1.
RX1-
TX1+
Output terminals for electrical standards IEC 61162-1 and RS-422.
"TX+" and "TX-" may be defined as "TX-A" and "TX-B" in IEC 61162-1.
TX1-
TX1
Output terminals for electrical standard RS-232C
GND
Ground terminal for RS-232C
2.3.3
Standard serial data channel assignment
First LAN adapter
Channel
Type
bit/s
1
rx/tx
4800
2
rx
4800
3
rx/tx
4800
4
rx/tx
4800
5
rx/tx
38400
6
rx
4800
7
rx
38400* Gyro1
8
rx
4800
Relay1
Relay NO
Relay2
Relay NC
Relay3
Relay NC
Second LAN adapter
Channel
Type
bit/s
9
rx/tx
4800
10
rx
4800
11
rx/tx
4800
12
rx/tx
4800
13
rx/tx
38400
14
rx
4800
15
rx
38400* Wind Sensor
16
rx
4800
Relay4
Relay NC
Relay5
Relay NC
Relay6
Relay NC
Note: For Relay 2 to 6: Polarities are depending on Relay outputs settings (Normal open or
Normal Close) of "Alarm Inputs+Outputs/AMWSS". (Not available for program version
05.xx)
2-12
Default use
ARPA2
Pos1
Track pilot
ARPA1
AIS
Pos2
Log/Dual-axis log
Operator fitness
Any ECDIS alarm
Backup navigator
*Program version 05.xx: 4800
Default use
Route Backup
Engine Control
AMWSS
Navtex (Not available for program version 05.xx)
B-Adapter
Echo Sounder
Water temp
Waypoint approach
Outside channel limit
Depth below limit
*Program version 05.xx: 4800
2. WIRING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fea-2807Fea-2107Fea-2107-dFea-2807-d

Table of Contents