5. RADAR SWITCH (OPTION)
Radar selector
Make five holes (one for toggle switch) to mount the switch on the desktop or bulkhead as
below.
Connection
Connect cables as below.
XH8P-NH8P cable
(10/20/30 m, option)
5-2
4-M3
70
Radar selector
To Processor unit for ECDIS
XH5P-XH10P-L1.6M cable
(supplied with option kit)
J205
J202
No.1 Radar
12
16.4
XH12P-DSUB15BNC2 cable
(supplied with option kit)
J206
J201
J203
XH3P-2P-L2000 cable
(supplied with option kit)
No.2 Radar
SW sheet
Water proofing gasket
Switch cap
D-spring
1.8
6
12 or 24 VDC