Comtech EF Data CDM-425 Installation And Operation Manual page 358

Advanced satellite modem (18 kbps – 25 mbps)
Table of Contents

Advertisement

Command
Length of
Parameter
(Instruction
Arguments
& Qualifier)
G.703 Clock
CEX=
2 bytes
Extension
Tx BERT
BTX=
1 byte,
State
0 or 1
Rx BERT
BRX=
1 byte,
State
0 or 1
Tx BERT
TBP=
1 byte
Pattern
Serial Remote Control
Description of Arguments
Command or Query. (FAST option)
Sets or returns G.703 Clock Extension in the form ab, where:
a=G.703 Clock Extension Mode
0=None
1=TxLock
2=RxEnable
b=G.703 Clock Extension Interface
0=T1
1=E1Bal
2=E1Unbal
EXAMPLE: <0/CEX=12 (Sets Tx Lock to E1 Unbalanced)
NOTES:
1) Not all CEX modes are valid all the time.
2) For argument a:
If Data Interface (ITF) is G.703, only 0=None is allowed.
If Tx clock (TCK) is not Internal, 1=TxLock is not allowed.
Command or Query.
Sets or returns Tx BERT State in the form x, where:
0=Off
1=On
EXAMPLE: <0/BTX=1 (Tx BERT On)
Command or Query.
Sets or returns Rx BERT State in the form x, where:
0=Off
1=On
EXAMPLE: <0/BRX=1 (Rx BERT On)
Command or Query.
Sets or returns Tx BERT Pattern, in the form x, where:
0=space
1=mark
2=1:1
3=1:2
4=63
5=511
6=2047 (DEFAULT)
7=2047R (or 2047 Alternate)
8=Mil-188
9=2^15-1
A=2^20-1
B=2^23-1
EXAMPLE: <0/TBP=6 (Tx BERT Pattern is 2047)
8–34
CDM-425 Advanced Satellite Modem
Revision 0
Query
Response to
(Instruction
Response to Query
Command
& Qualifier)
CEX=
CEX?
CEX=ab
CEX?
(see Description of
CEX*
Arguments)
CEX#
BTX=
BTX?
BTX=x
BTX?
(see Description of
BTX#
Arguments)
BRX=
BRX?
BRX=x
BRX?
(see Description of
BRX#
Arguments)
TBP=
TBP?
TBP=x
TBP?
(see Description of
TBP#
Arguments)
MN-CDM-425

Advertisement

Table of Contents
loading