Comtech EF Data CDM-425 Installation And Operation Manual page 355

Advanced satellite modem (18 kbps – 25 mbps)
Table of Contents

Advertisement

Command
Length of
Parameter
(Instruction
Arguments
& Qualifier)
Clear All
CAS=
None
Stored
Statistics
Initialize
ISP=
None
Statistics
Pointer
Force 1:1
FSW=
None
Switch
Outdoor Unit
ODU=
1 byte,
Comms
0 or 1
enable
1:N (One For
OFN=
1 byte,
N) control
0 or 1
IP Address
IPA=
18 bytes,
numerical
IP Gateway
IPG=
15 bytes,
numerical
Serial Remote Control
Description of Arguments
Command only.
This command takes no arguments. Forces the modem to clear the firmware statistics log.
EXAMPLE: <0/CAS=.
Command only.
Resets internal pointer to allow RNS? queries to start at the beginning of the statistics log.
Command only.
This command takes no arguments
Forces unit to toggle Unit Fail relay to "fail" state for approx 500ms. If unit is part of a 1:1 pair and is currently
the 'Online' unit, this forces a switchover, so unit is then in 'Standby' mode. The command is always executed
by the unit, regardless of whether it is standalone, in a 1:1 pair, or part of a 1:N system.
Command or Query.
Enables or disables communications, via the FSK link, with a Comtech EF Data transceiver (ODU) in the
form x, where:
0=Disabled
1=Enabled
Command or Query.
Enables or disables the 1:N control. This affects a control line on the 25-pin rear panel connector. This
must be enabled when the modem is attached to a CRS-300 1:N Controller or a CRS-500 1:N Switch in
the form x, where:
0=Disabled
1=Enabled
Command or Query.
Sets or returns the IP Address and network prefix for the 10/100 BaseT Ethernet management port, in the
form aaa.bbb.ccc.ddd.yy, where:
aaa=000-223
bbb=000-255
ccc=000-255
ddd=001-255
yy=08-30
EXAMPLE: <0/IPA=010.006.030.001.24
Command or Query.
Sets or returns the IP Gateway Address for the Ethernet Management port, in the form aaa.bbb.ccc.ddd,
where:
aaa=000-223
bbb=000-255
ccc=000-255
ddd=001-255
EXAMPLE: <0/IPG=010.006.030.001
8–31
CDM-425 Advanced Satellite Modem
Revision 0
Query
Response to
(Instruction
Response to Query
Command
& Qualifier)
CAS=
N/A
N/A
CAS?
CAS*
CAS#
ISP=
N/A
N/A
ISP#
FSW=
N/A
N/A
FSW*
ODU=
ODU?
ODU=x
ODU?
(see Description of
ODU*
Arguments)
ODU#
OFN=
OFN?
OFN=x
OFN?
(see Description of
OFN*
Arguments)
OFN#
IPA=
IPA?
IPA=
IPA?
aaa.bbb.ccc.ddd.yy
IPA*
(see Description of
IPA#
Arguments)
IPG=
IPG?
IPG=
IPG?
aaa.bbb.ccc.ddd (see
IPG*
Description of
IPG#
Arguments)
MN-CDM-425

Advertisement

Table of Contents
loading

Table of Contents