Functions Listed by Usage
Basic Functions
Usage
Set the cycle time to a fixed interval.
Stop PC operation when the cycle time exceeds a max-
imum setting.
Keep all outputs ON when PC operation stops.
Retain the contents of I/O memory when starting opera-
tion.
Retain the contents of I/O memory when the PC is
turned ON.
Eliminate effects from chattering and external noise.
Maintenance Functions
Usage
Record data with time-stamp.
Establish user-defined errors for desired input condi-
tions. (Fatal and non-fatal errors can be defined.)
Read the number of power interruptions.
Set the startup operating mode.
Communications Functions
Usage
Read/write I/O memory data and change the operating
mode from a host computer.
Connect to a serial device such as a bar code reader or
serial printer.
Make a high-speed connection with an OMRON Pro-
grammable Terminal.
Make a PC-PC data link connection with another
CPM2C, or a CPM1, CPM1A, CPM2A, SRM1, CQM1,
C200HS, or C200HX/HG/HE PC.
Connect a Programming Console.
Connect a personal computer running SYSMAC Sup-
port Software (SSS) or SYSMAC-CPT Support Soft-
ware.
Monitor equipment with a Programmable Terminal and
program the PC with a Programming Device.
26
Function
Set a minimum (fixed) cycle time in the PC Setup.
Set a maximum (watch) cycle time in the PC Setup.
Turn ON the IOM Hold Bit (SR 25212).
Turn ON the IOM Hold Bit (SR 25212).
Turn ON the IOM Hold Bit (SR 25212) and set the PC
Setup (DM 6601) so that the status of the IOM Hold Bit
is maintained at startup.
Set a longer input time constant in the PC Setup.
Function
Clock/calendar function
FAL(06) defines non-fatal errors. (PC operation contin-
ues.)
FALS(07) defines fatal errors. (PC operation stops.)
The number of power interruptions is stored in AR 23.
Set the startup operating mode in the PC Setup
(DM 6600).
Function
Host Link communications (Set the communications
mode to Host Link in the PC Setup.)
No-protocol communications (Set the communications
mode to no-protocol in the PC Setup.)
1:1 NT Link (Set the communications mode to 1:1 NT
Link in the PC Setup.)
1:1 PC Link (Set the communications mode to 1:1 PC
Link in the PC Setup.)
Connect the Programming Console to the peripheral
port via the communications port. (Turn OFF Communi-
cations Switch 2.)
The computer can be connected to the peripheral port
or RS-232C port via the communications port.
The RS-232C port and peripheral port can be used
simultaneously via the communications port.
Section 1-4
Refer
to
Page
101
Page
93
Page
93,
100
Page
102
Refer
to
Page
98
W353
Page
100
Refer
to
W353
Page
160
Page
78,
159
W353
Page
81,
160