Wiring and Connections
Note
One-to-N Host Link
Connection
IBM PC/AT or
compatible
computer
When using the port
as a peripheral port
CPM2-CIF11
When using the port
as an RS-232C port
XW2Z-070T-1 (0.7 m)
XW2Z-200T-1 (2 m)
CPM2-CIF01-V1
Note
80
1. The CS1W-CN226/626 Connecting Cables can be used, but the CS1W-
CN225/625 and CS1W-CN227/627 Connecting Cables cannot be used.
2. The CQM1-CIF11 Connecting Cable cannot be used. (If one is connected,
the CPM2C-S will not recognize it; the PC will enter RUN mode at startup
if pin 4 of the DIP switch is ON and the PC Setup (DM 6600) is set so that
the Programming Console's mode switch controls the startup mode.)
3. Refer to SECTION 8 Using Programming Devices for details on the Sup-
port Software that can be used with the CPM2C-S.
Up to 32 OMRON PCs, including CPM2C-S PCs, can be connected to a host
computer.
Connecting Cable
XW2Z-200S-V (2 m)
XW2Z-500S-V (5 m)
B500-AL004 or NT-AL001 (requires +5 V)
(See notes 1 and 2.)
RS-422 (Total length: 500 m max.)
CPM2C-S
CPU Unit
NT-AL001
(See note 1.)
RS-232C port
CPM2C-S
CPM2C-S
CPU Unit
CPU Unit
Up to 32 PCs
1. The NT-AL001 must be supplied externally with 5 VDC. When an NT-
AL001 is connected to a CPM2C-S PC, pin 6 of the CPM2C-S' RS-232C
port supplies +5 VDC and an external power supply is not necessary.
2. The B500-AL004 requires an external AC power supply (110 VAC or
220 VAC).
3. Be sure that the power supply requirements of the CPU Unit, Expansion
Units, and Expansion I/O Units do not exceed the available capacity. Also,
take into account the power consumption of the NT-AL001 Adapter when
an NT-AL001 Adapter is connected to the RS-232C port.
CPM2C-S
CPU Unit
CPM2-CIF11
NT-AL001
(See note 1.)
XW2Z-070T-1 (0.7 m)
XW2Z-200T-1 (2 m)
RS-232C port
CPM2C-CN111
Connecting Cable
(0.15 m)
Section 3-4
CPM2C-S
CPU Unit
CPM2-CIF11
NT-AL001
(See note 1.)
XW2Z-070T-1 (0.7 m)
XW2Z-200T-1 (2 m)
CPM2C-S
RS-232C port
CPU Unit
CSW1-CN118 Con-
necting Cable (0.1 m)

Hide quick links: