ADJ 9.1 Max Setup
Purpose
To conduct a check of the machine and set it up so that excellent copy quality can be consis-
tently obtained by stabilizing the development potential and copy density.
Adjustment
Max Setup consists of 5 separate adjustments that should be performed in the following
sequence:
1.
ADJ
9.7, IIT Calibration (dC945)
NOTE: Perform
ADJ 9.2
only when replacing the ATC Sensor or Developer Housing.
2.
ADJ
9.2, ATC Sensor Setup (dC921)
3.
ADJ
9.3, TRC Control/Toner Density Setup (dC922)
4.
ADJ
9.4, ADC Output (dC934)
NOTE: Perform ADJ 9.5 only when the customer requests.
5.
ADJ
9.5, Manual TRC Adjust (dC924)
Initial issue
DC 3535/2240/1632
02/03
4-163
Repairs and Adjustments
ADJ 9.1