Exception Error - Xerox DocuColor 2240 Service Manual

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

116-324 Exception Error

CPU exceptional error.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Replace the ESS PWB
(PL
13.1).
Initial issue
DC 3535/2240/1632
116-325 ESS Fan
ESS Fan failure is detected or +24 VDC is failed.
Procedure
Remove Rear Cover
(REP
14.2).
Remove cover from +24V LVPS
Disconnect P502 on +24V LVPS
Check that power is switched off. Measure resistance of fuse on +24V LVPS. Resistance is 1
ohm or less.
Y
N
Replace +24V LVPS
(PL
9.1).
Switch on the power. Measure the AC voltage between the white and black wires in
the +24 VDC. Line Voltage AC is measured.
Y
N
Go to the
OF 1-4
RAP.
Connect the black meter lead to ground (-). Measure DC voltage at
(Figure
1). Voltages are measured as shown
Y
N
There is a problem with the +24 VDC enable circuit. Go to
Ensure
P/J502
is still disconnected on the +24V LVPS. Measure the DC voltage at
the +24V LVPS
(Figure
1). Voltages are measured as shown.
Y
N
Replace the 24V LVPS
(PL
9.1).
Connect
P/J502
on the +24V LVPS. Measure the DC voltage at
(Figure
1). Voltages are measured as shown.
Y
N
There is a short circuit in +24 VDC distribution. Refer to Section 7 wirenets for +24 VDC
distribution.Disconnect the connectors in the distribution network. Switch the power on.
Connect the connectors while monitoring +24 VDC. The +24 VDC supply will shut down
when the P/J with the shorted circuit is connected.
Replace the ESS Fan
(PL
13.1).
If the problem continues, replace the ESS PWB
+24 VDC RET
Vio (all on top)
+24 VDC
Orn (all)
Figure 1 P502, P505 on +24V LVPS
02/03
2-463
(PL
9.1).
(Figure
1).
P/J505
on the +24V LVPS
(Figure
1).
OF
1-3.
P/J502
on the +24V LVPS
(PL
13.1).
+24V, 0V, +3.3V, +5V
Status Indicator RAPs
116-324, 116-325
P/J2
on
P/J502
on