Duplex (Side 2) Registration
Purpose
The purpose of this procedure is to correctly position the lead edge and side edge of the image
in relation to the edge of the paper.
Check
1.
Ensure that Paper Tray 1 contains paper and that the paper guides are adjusted correctly.
If available, load the tray with 11 x 17 in. or A3 paper.
2.
Select Duplex (Side 2) in the Lead Edge column.
NOTE: Side 2 will be face down in the output tray.
3.
Press the Start button on the screen. As the prints are made, mark each to indicate the
lead edge.
4.
Check Lead Edge:
Check the Side 2 Lead Edge Registration
21.6mm±0.5, perform the Adjustment.
5.
Check Side Edge:
Check the Side Edge Registration
perform the Adjustment.
Adjustment
Duplex Lead Edge:
1.
Use the Right and Left Arrow buttons to move the image toward or away from the lead
edge of the paper. Each click on the button moves the image 0.25mm. The cumulative
amount of shift is indicated in the Lead Reg. box.
2.
After adjusting the registration, click Set Adjust Value.
NOTE: Changes made to the NVM
machine exits Diagnostic Mode.
3.
Go to the Service Exit tab and select Temporary Closeout.
4.
After the machine reboots and is ready to copy, reconnect the PWS
5.
Select Start.
6.
Repeat the check/adjustment until the specifications are met.
7.
Select Save [LR] to save the new NVM settings.
Duplex Side Edge:
1.
Select Duplex (Side 2) in the Side Edge column
2.
Use the Up and Down Arrow buttons to move the image toward or away from the out-
board edge of the paper. Each click on the button moves the image 0.21mm. The cumula-
tive amount of shift is indicated in the Side Reg. box.
3.
After adjusting the registration, click Set Adjust Value.
4.
Select Start.
5.
Repeat the check/adjustment until the specifications are met.
6.
Select Save [SR] to save the new NVM settings.
Repairs and Adjustments
ADJ 9.9
(Figure
1). If the measured value is not
(Figure
1). If the measured value is not 21.6mm±0.5,
for LE registration are not implemented unless the
Lead Edge Registration for Tray 5 (MSI)
Purpose
NOTE: There are three settings for Tray 5 Lead Edge; one for standard weight paper, one for
heavyweight stock, and one for extra-heavyweight stock.
To correctly set the lead edge of the image in relation to the edge of the paper.
Check
1.
Load Tray 5 with the largest standard weight paper used by the customer.
2.
Select Tray 5 (MSI) in the Lead Edge column.
3.
Press the Start button on the screen. As the prints are made, mark each to indicate the
lead edge.
4.
Take the third pattern that was printed and measure from the lead edge to point 'A' on
ure 1
(the intersection of the 7th line from the left edge and the first line from the lead
edge).
5.
If the measured value is not 21.6mm±0.5, perform the Adjustment.
6.
If the customer uses heavyweight or extra-heavyweight stock, load Tray 5 with the stock.
Select Tray 5 (HW) or Tray 5 (XHW), as appropriate. Repeat the check.
Adjustment
1.
Use the Right and Left Arrow buttons to move the image toward or away from the lead
edge of the paper. Each click on the button moves the image 0.25mm. The cumulative
amount of shift is indicated in the Lead Reg. box.
2.
After adjusting the registration, click Set Adjust Value.
NOTE: Changes made to the NVM for LE registration are not implemented unless the machine
exits Diagnostic Mode.
3.
Go to the Service Exit tab and select Temporary Closeout.
4.
After the machine reboots and is ready to copy, reconnect the PWS.
5.
Select Start.
6.
Repeat the check/adjustment until the specifications are met.
7.
Select Save [LR] to save the new NVM settings.
02/03
4-172
Fig-
Initial issue
DC 3535/2240/1632

Advertisement

Table of Contents
loading