12-911 Stacker Lower Safety Warning
The Height Alignment was not successful during Stacker Tray lowering while stacking.
Initial Actions
Check the Stack Height Sensor Actuator for disengagement, bending, obstruction and break-
age
(Figure
1).
Procedure
Remove paper from Stacker Tray. The problem continues.
Y
N
Return to Service Call Procedures.
Enter
dC330
[012-201] and press Start. Actuate the Stack Height Sensor
play changes.
Y
N
Press Stop. Check the circuit of the Stack Height Sensor
RAP for troubleshooting procedure.
Press Stop.
•
Ensure that the connectors shown in the circuit diagram
nected and that the wires are not damaged.
•
Replace the Stack Height Sensor
(PL
•
If the problem persists, replace the Finisher PWB
Stack
Height
Sensor
Figure 1 Component Location
Status Indicator RAPs
12-911
(PL
17.6). The dis-
(Figure
2). Refer to the
(Figure
2) are securely con-
17.6).
(PL
17.13)
(Figure
3).
Stacker
Motor
OF 99-2
Figure 2 12-911 RAP Circuit Diagram - Stack Height Sensor
02/03
2-286
Figure 3 Finisher PWB
DC 3535/2240/1632
Initial issue